[Technical Data] Automatic Pretreatment of DEENA2 Steel with Nitric Acid - Hydrochloric Acid (Aqua Regia)
A study was conducted on the addition of nitric acid-hydrochloric acid (aqua regia) for the heating decomposition (dissolution) in the analysis of impurities contained in iron and steel.
last updated
-
Technical Data: Automatic Pre-treatment with Mixed Acid in DEENA2 Operating Environment Measurement and Analysis
Automatic pretreatment using mixed acid (hydrochloric acid: nitric acid: pure water = 2:1:4) in work environment measurement analysis with DEENA2.
last updated
-
Technical Data: Automatic Pre-treatment with Aqua Regia in Work Environment Measurement and Analysis
Automatic pretreatment using aqua regia (nitric acid: hydrochloric acid = 1:3) in work environment measurement analysis with DEENA3.
last updated
-
Technical Data: Automatic Pre-treatment Using Hydrofluoric Acid and Nitric Acid
Automated pretreatment using hydrofluoric acid and nitric acid in the decomposition of silica with DEENA3.
last updated
-
Establishment of a Nutritional Component Analysis Method for Food Using Near-Infrared Analysis Equipment
Measurement was conducted using a nutrition analyzer, and a comparison of the results with conventional method values.
last updated
-
"Analysis Work Efficiency Improvement WEB Online Seminar" *Free Participation*
We propose work efficiency improvements using Continuous Flow Analysis (CFA) and Near-Infrared Analysis (NIR) devices. We will also introduce some examples.
last updated
-
Continuous Flow Analysis System (CFA) "MiSSion"
Compatible with halogen and LED light sources! Vertical 2-channel system of the auto analyzer series.
last updated
-
Automatic Spectrophotometer "Discrete Analyzer AQ400"
Automate everything from preprocessing to analysis, reducing labor and minimizing human errors! Supports various analysis items.
last updated
-
Near-infrared analyzer "Nutrient component analysis device in food 2600XT-R"
Measurement time is as short as 30 seconds! No reagents are required, and operation is simple. This is in response to the obligation for nutritional labeling.
last updated
-
[Presentation of Materials] Introduction of simple, quick, and accurate measurement examples of nutritional components!
"What is near-infrared analysis? An explanation of the basic knowledge." The inevitable obligation for nutritional labeling. What are the analysis methods for processed foods using near-infrared analysis devices that require minimal effort?
last updated
-
[Presentation of Materials] Introduction of simple, rapid, and accurate measurement examples of nutritional components!
Utilizing near-infrared analysis equipment. By leveraging over 1,000 measurement data points, it is possible to measure nutritional components with accuracy equivalent to conventional methods!
last updated
-
Automatic Dilution Device "Syringe Dilutor 3"
Automation of operations solves issues during standard solution preparation and sample dilution!
last updated
-
Acid decomposition pretreatment device 'DEENA3' / 'Syringe Dilutor 3'
Fully automated from acid decomposition pretreatment to sample preparation! Easy operation also avoids human error.
last updated
-
Study on the decomposition using hydrofluoric acid and nitric acid in the analysis of impurities in silica.
[Technical Data Presentation] Automation of Reagent Preprocessing Using Acid Decomposition Pretreatment Device DEENA
last updated
-
Near-infrared analyzer "Soy Sauce Component Analysis Device Spectruster XT-R"
Simultaneously and rapidly measure the total nitrogen, salt-free soluble solids, salt, and alcohol content of soy sauce. Just place the soy sauce on the auto-sampler.
last updated
-
Near-infrared analyzer "Synthetic Resin Analysis Device Spectraster XT-R"
All types of polymer compounds can be easily measured within 30 seconds of analysis time, without any pre-treatment, across raw materials, process management, and product inspection.
last updated
-
Examples of the use of Continuous Flow Analysis (CFA method) in environmental analysis, among others.
Examples of the use of CFA method in environmental analysis and efforts for the restoration of Lake Shinji.
last updated
-
An analysis case using the CFA method for measuring nitrogen and phosphorus in seawater, etc.
Publication of case studies using the CFA method for the measurement of total nitrogen and total phosphorus in seawater and wastewater.
last updated
-
Analysis examples of fluoride and cyanide using Continuous Flow Analysis (CFA method).
Introduction to case studies on the analysis of fluoride and cyanide using an autoanalyzer!
last updated
-
Fertilization for the oligotrophication of the Seto Inland Sea and the increase of shellfish production.
Introduction of a paper discussing "Eutrophication of the Seto Inland Sea and fertilization for increased shellfish production."
last updated
-
Study on the decomposition using nitric acid in the analysis of Cd and other elements in rice and rice ears.
[Free Technical Data Available] Fully automated from stirring and heating to mixing! Contributes to significant reduction in work time!
last updated
-
Study on the decomposition using nitric acid-hydrochloric acid (aqua regia) in the analysis of impurities in iron and steel.
[Free Technical Materials Available] Successfully automated tasks previously done by hand! No need for reagent preparation, achieving improved work efficiency!
last updated
-
Fully automatic pretreatment device for acid decomposition, 'DEENA'
Many achievements in fields such as steel, semiconductors, environment, and agriculture. Free vials for the first 10 companies!
last updated
-
Near Infrared Analysis Device for Food Nutritional Component Measurement - Spectraluster XT
Without any preprocessing, you can easily measure calories, protein, fat, carbohydrates, and sodium (salt) in about 30 seconds. No computer required.
last updated
-
Near-infrared analyzer "Feed Ingredient Analysis Device Spectraster XT-R"
Nutritional components in feed can be measured using near-infrared light.
last updated
-
Near-infrared analyzer "Food Component Analysis Device Spectruster XT-R"
Moisture, protein, and ash content in flour and similar products can be rapidly measured using near-infrared light.
last updated
-
Automatic Colorimetric Analyzer AQ400
The process of adding reagents, weighing, and colorimetry is performed fully automatically using a discrete method.
last updated
-
[Demo unit available for loan] Fully automatic acid heating decomposition pretreatment device DEENA.
Pre-treatment device for measuring metal components in drainage, soil, and drinking water. It can automatically dilute, add reagents, and make up solutions. Ideal for acid decomposition of glass and metals.
last updated
-
Cooling Water Measurement Device Quattro
The hardness, alkalinity, sulfate ions, silica, and iron ions of the cooling water cooling tower can be measured. (Continuous flow analysis method is used.)
last updated
-
Anionic Surfactant Measurement Device Auto Analyzer Type 3
Anionic surfactants in environmental water and drinking water can be measured (using a continuous flow analysis method).
last updated