【Q&A】What is the maximum temperature that sterilization and cleaning processes can withstand?
We will answer your valve concerns!
Q: Is it possible to sterilize and clean the piping of a manual diaphragm valve at 120°C (SIP/CIP)? Additionally, what is the expected temperature rise at the handle during this process? A: The maximum temperature for steam sterilization is 150°C, and the temperature rise at the handle is approximately 45°C, so it can be safely operated even after the sterilization process. *Please inquire as the heat resistance duration may vary depending on the diaphragm. *For autoclave processing, some products may not be compatible, so please inquire.
basic information
For GEMÜ diaphragm valve model 601: 【Nominal diameter】4A to 15A 【Applicable fluids】Inert and corrosive liquids and gases 【Fluid temperature】-10 to 100°C 【Sterilization temperature】Below 150°C 【Operating pressure】0 to 1.0 MPa 【Ambient temperature】0 to 60°C 【Body material】Stainless steel 【Diaphragm material】FPM, EPDM, PTFE 【Connections】Butt welding, threaded connection, ferrule, and other various standards
Price range
Delivery Time
Applications/Examples of results
Usage example: - Manufacturing equipment for liquid pharmaceuticals, etc.