[Reference Data] Filtration Separation Capability
Conducted tests using the MG-50W fully automatic centrifuge! Confirmed the changes in filtration performance.
We would like to introduce reference data on filtration and separation capabilities. The test model is the "MG-50W Automatic Centrifuge," with centrifugal forces of 1700G and 2500G. We circulated and filtered 90L of contaminated liquid (industrial water) mixed with glass processing sludge at a concentration of 30,000 mg/L, and collected samples at different centrifugal forces: original solution ⇒ 1 pass (after 3 minutes) ⇒ 5 passes (after 15 minutes) ⇒ 10 passes (after 30 minutes) to confirm the changes in filtration performance. As a result, at a centrifugal force of 1700G, the SS concentration after 1 pass was 5,400 mg/L, and after 10 passes, it was 68 mg/L. At a centrifugal force of 2500G, the SS concentration after 1 pass was 3,300 mg/L, and after 10 passes, it was 28 mg/L. Detailed test results can be viewed via the related links. [Overview] <Test Model> ■ MG-50W Automatic Centrifuge ■ Centrifugal Force: (1) 1700G, (2) 2500G ■ Flow Rate: 30L/min *For more details, please refer to the PDF document or feel free to contact us.
basic information
[Test Results] <Centrifugal Force 1700G> ■Original Solution: SS Concentration 28,000 mg/L ■1 Pass: SS Concentration 5,400 mg/L ■5 Passes: SS Concentration 460 mg/L ■10 Passes: SS Concentration 68 mg/L <Centrifugal Force 2500G> ■Original Solution: SS Concentration 29,000 mg/L ■1 Pass: SS Concentration 3,300 mg/L ■5 Passes: SS Concentration 240 mg/L ■10 Passes: SS Concentration 28 mg/L *For more details, please refer to the PDF document or feel free to contact us.*
Price range
Delivery Time
Applications/Examples of results
For more details, please refer to the PDF document or feel free to contact us.
catalog(1)
Download All CatalogsRecommended products
Distributors
We confidently recommend our "fully automatic centrifuge."