[Reference Data] Filtration Separation Capability
Conducted tests using the MG-50W fully automatic centrifuge! Confirmed the changes in filtration performance.
We would like to introduce reference data on filtration and separation capabilities. The test model is the "MG-50W Automatic Centrifuge," with centrifugal forces of 1700G and 2500G. We circulated and filtered 90L of contaminated liquid (industrial water) mixed with glass processing sludge at a concentration of 30,000 mg/L, and collected samples at different centrifugal forces: original solution ⇒ 1 pass (after 3 minutes) ⇒ 5 passes (after 15 minutes) ⇒ 10 passes (after 30 minutes) to confirm the changes in filtration performance. As a result, at a centrifugal force of 1700G, the SS concentration after 1 pass was 5,400 mg/L, and after 10 passes, it was 68 mg/L. At a centrifugal force of 2500G, the SS concentration after 1 pass was 3,300 mg/L, and after 10 passes, it was 28 mg/L. Detailed test results can be viewed via the related links. [Overview] <Test Model> ■ MG-50W Automatic Centrifuge ■ Centrifugal Force: (1) 1700G, (2) 2500G ■ Flow Rate: 30L/min *For more details, please refer to the PDF document or feel free to contact us.
basic information
[Test Results] <Centrifugal Force 1700G> ■Original Solution: SS Concentration 28,000 mg/L ■1 Pass: SS Concentration 5,400 mg/L ■5 Passes: SS Concentration 460 mg/L ■10 Passes: SS Concentration 68 mg/L <Centrifugal Force 2500G> ■Original Solution: SS Concentration 29,000 mg/L ■1 Pass: SS Concentration 3,300 mg/L ■5 Passes: SS Concentration 240 mg/L ■10 Passes: SS Concentration 28 mg/L *For more details, please refer to the PDF document or feel free to contact us.*
Price range
Delivery Time
Applications/Examples of results
For more details, please refer to the PDF document or feel free to contact us.