Ultrasonic Flow Meter | Display Separate Type UA102-S/HiT Series
Just clamp it between the pipes and tighten the screws! Large diameter and high temperature compatible, easy installation ultrasonic flow meter.
The UA102-S/UA102-HiT series requires no processing of the piping as the detectors are simply installed on the outside of the pipes. The display unit is separate, and two types are available, including one that can handle high temperatures. There is a separate type for 125A to 200A (for large diameter pipes) and a separate high-temperature type. Fluid temperature range: UA102-S series (0 to 80°C) / UA102-HiT series (0 to 150°C) Main features: - Compatible with large diameter piping - Suitable for outdoor installation - Capable of handling high-temperature fluids (HiT series) - Allows for flow monitoring and setting changes from a distance Operating principle: When ultrasonic waves propagate through a liquid, the propagation time changes compared to a stationary state if there is flow. When the ultrasonic signal is transmitted and received between the upstream and downstream detectors/transducers through the moving liquid, a difference in passage/propagation time occurs between upstream and downstream. The flow velocity/flow rate is calculated from this time difference and indicated/outputted. For more details, please contact us or download the catalog.
basic information
Main Specifications Measurement Flow Rate Range: 0.1 to 5.0 m/s Measurement Accuracy: ±1.0% F.S. Reproducibility: ±0.8% Measurable Fluids: Water, seawater, oil, chemicals, etc. (*1) Output: 4-20 mA DC Communication: RS485 Power Supply: 24 V DC (Power Consumption: 3 W) Compatible Piping: Steel pipe, stainless steel pipe, PVC pipe Display: Instantaneous/accumulated flow values, ultrasonic reception sensitivity values Power Cable: M12 connector, 5-core, 2 m Transducer Cable: M12 connector, 2 m Keypad: 4 touch buttons Housing: Aluminum alloy Fluid Temperature Range: 0 to 80°C, 0 to 150°C Ambient Temperature Range: 0 to 50°C Protection Rating: Transducer: IP54, Detector: IP65 (*1) Regarding the measurement of oil and chemicals Some oils and chemicals may contain fluids that cannot be measured (e.g., those with high viscosity that are difficult for ultrasonic waves to pass through). Please conduct a demonstration at the intended installation location, piping, and measurement fluid in advance to confirm accurate measurement. ● For more details, please contact us or download the catalog.
Price range
Delivery Time
Model number/Brand name
UA102-Sani Series
Applications/Examples of results
Main Uses Suitable for high-temperature fluids such as food washing (CIP) liquids. ● For more details, please contact us.
Related Videos
catalog(11)
Download All Catalogs