[Test, Experiment, Analysis System] Radiation Immunity Test System
You can evaluate malfunctions and degradation! By using G-TEMCELL, testing can be safely conducted even without an anechoic chamber.
This system is an "Electromagnetic Immunity Testing System" that evaluates the electromagnetic resistance of test samples when exposed to electromagnetic fields. It irradiates electromagnetic noise at specified frequencies and test levels, allowing for the assessment of malfunctions or degradation of customer products. Additionally, by using the G-TEMCELL, testing can be conducted safely without the need for an anechoic chamber. The test frequency ranges from 100 kHz to 3 GHz as standard, and AM, FM, and pulse modulation can also be applied. 【Features】 ■ Improvement of operational efficiency - By managing data collectively, operational efficiency is increased. - More efficient operation of expensive equipment. ■ Reduction of burden - Reduces the burden on operators and administrators. - Safety interlock circuits help prevent accidents in advance. *For more details, please refer to the related links or feel free to contact us.
basic information
**System Implementation Overview** **Background of Implementation** - The advantage of GTEM testing is that it does not require particularly expensive antennas or anechoic chambers in the high-frequency range, allowing for significant cost reductions compared to previous testing methods. - In recent years, the importance of high-frequency EMC testing has increased significantly, and GTEM enables the introduction of low-cost testing facilities. **Purpose of Implementation** - Reduction of Burden - Minimize the burden on operators (work hours for measurement and comparison, etc.) and create a system that does not depend on individual technical levels. - Efficiently operate equipment (such as measuring instruments located alongside anechoic chambers and shielded rooms). - Reporting Functionality - Easily create comparison reports (such as lists of test results). - Safe Testing - Operate EMS testing safely with various interlock functions to prevent accidents. *For more details, please refer to the related links or feel free to contact us.*
Price range
Delivery Time
Applications/Examples of results
【Usage】 ■Electrical and automotive related <EMS (Electromagnetic Resistance)> *For more details, please refer to the related links or feel free to contact us.