[Case Study] High Pressure HydraCell Pump Chemical Product Manufacturer
We will introduce case studies of the introduction of our pumps as replacements for competitor pumps in high-pressure cleaning applications.
We would like to introduce a case study from a chemical product manufacturer that produces a wide range of products, from liquid soap to insecticides. Initially, a centrifugal pump was used as a high-pressure pump for cleaning, but it was found to have low durability and high maintenance costs after use. The "HydraCell G25 model" was adopted instead of the centrifugal pump, and since then, there have been no issues at all. *For more details, please refer to the PDF document or feel free to contact us.
basic information
【Before】 ■Centrifugal Pump ・Required Power: 37kW ・Flow Rate: 60LPM ・Pressure: 6.0MPa ↓ 【After】 ■HydraCell G25 Model ・Required Power: 11kW (Energy Saving) ・Flow Rate: 63LPM ・Pressure: 7.0MPa ・Initial costs are 60% lower compared to centrifugal pumps ・Capable of transporting high-temperature liquids with low lubricity without any issues *For more details, please refer to the PDF document or feel free to contact us.
Price range
Delivery Time
Applications/Examples of results
For more details, please refer to the PDF document or feel free to contact us.