Information on the production case of the "coolant tank unit."

サノテック
The "coolant tank unit" configuration varies depending on the customer's usage conditions, including "machining equipment / machined parts / coolant fluid / processing flow rate." We present seven examples with different usage conditions, clearly indicating the appropriate equipment configuration for each condition, along with the effectiveness points. <Example of Usage Conditions> ◆ Usage Conditions - Machining Equipment: Cylindrical Grinding Machine - Machined Parts: Automotive Parts - Material: SCM Material - Coolant Fluid Used: Water-soluble - Processing Flow Rate: 200 L/min ◆ Production Example - Unit Configuration: - Primary Filtration: Magnetic Separator with Rare Earth Magnet Specification - Secondary Filtration: Cyclone Separator - Tank: Oval Type, 2 Tanks - Approximate Dimensions: Width 2500 × Depth 100 × Height 2000 mm (Effectiveness Points) By using an oval-shaped tank and circulating the coolant within the tank, cleaning work is reduced. ★ For more details, please check the "catalog." - Sales Agent: Sanotech Co., Ltd. - Manufacturer: Sumitomo Heavy Industries Fine Technology, Ltd. (Explanation will be provided by the manufacturer.)