Level Crossing Fault Detection Device Type N2A
When the memory content exceeds capacity, it will overwrite the oldest data. Always keeping the latest data in memory.
The "Level Crossing Fault Detection Device N2A Type" is a device that monitors the operational status of relay-type level crossing equipment, capable of determining and storing various faults. It is compatible with various centralized monitoring devices. When the memory capacity is exceeded, it will overwrite the oldest data. Our company utilizes the technology developed through the selection of LEDs and circuit board layout for railway signals and displays to carry out development design and manufacturing (prototype mass production). We solve your problems, such as "I want a warning device like this" or "Can you make something like this with LEDs?" so please feel free to contact us. [Types] ■AGT Built-in Type ■AGT Retrofit Type ■AGT External Type *For more details, please download the PDF or feel free to contact us.
basic information
【Specifications and Performance (Partial)】 ■ Rated Voltage: DC26.2V Ripple content 5% or less (with battery or smoothing circuit power supply) ■ Current Consumption: 1.1A or less (at rated voltage) ■ Memory Capacity: 500 changes (Fault information: 50 changes) ■ Dimensions (W×H×D): 250×185×189mm (excluding protrusions) *For more details, please download the PDF or feel free to contact us.
Price range
Delivery Time
Applications/Examples of results
For more details, please download the PDF or feel free to contact us.