富山電気ビルデイング Official site

Reverberation Chamber

TDK Corporation performance design! We have signed a business collaboration agreement with a Japanese shield enclosure manufacturer.

We offer the construction of "Reverberation Chambers." Compatible with various automotive and consumer immunity standards. We can also accommodate automotive 200V/m irradiation tests and radar pulse tests. We have both 80MHz and 200MHz types in our lineup. Our unique stirrer structure enables a wide working volume. 【Features】 ■ Compatible with various automotive and consumer immunity standards ■ Supports automotive 200V/m irradiation tests and radar pulse tests ■ Achieves a wide working volume with a unique stirrer structure ■ Available in 80MHz and 200MHz types *For more details, please refer to the PDF materials or feel free to contact us.

Related Link - https://www.toyamadenbil.co.jp/merchandise/

basic information

[80MHz Type Specifications] ■ Lower limit frequency: 80MHz ■ Chamber internal dimensions (m): 10.1×6.4×4 ■ Working volume (m): 4.8×3.5×3.1 ■ Applicable standards: ISO11452-11, IEC61000-4-21, RTCA DO-160G ■ Stirrer: Fractal structure (continuous rotation, step rotation) *For more details, please refer to the PDF document or feel free to contact us.

Price range

Delivery Time

Applications/Examples of results

[Example of Achievements] ■ KEC Kansai Electronic Industry Promotion Center *For more details, please refer to the PDF document or feel free to contact us.*