Gamma ray density meter (non-contact density meter)
The density (concentration) of the fluid inside the pipe is measured from the outside of the pipe. No processing of the pipe is required.
Our gamma-ray density meter PM-1000ExNC measures completely non-contact by simply being clamped onto existing piping without any processing. Conventional density (concentration) meters of other types require the sensor part to come into contact with the fluid, which can lead to sensor failure under acidic, alkaline, high-temperature, or high-pressure conditions. Additionally, in the case of slurries, the sensor may become stuck, gradually causing measurement errors until it can no longer measure. The sensor part of the PM-1000ExNC does not come into contact with the fluid, and there is no pressure applied within the piping. Furthermore, by providing appropriate insulation between the piping and the sensor part, there is no influence from temperature. Therefore, it can measure fluids under acidic, alkaline, high-temperature, high-pressure conditions, and slurries without any issues. If you are troubled by problems with other methods, please consider the PM-1000ExNC. It uses weak gamma rays and is safe as it is not subject to regulations. 【Features】 - No need for the appointment of a supervisor, setting of controlled areas, or notifications (it uses a defined quantity of radiation source below regulatory limits). - Lightweight and easy to install on existing piping. - Can be installed in a small space. *For more details, please download the PDF or feel free to contact us.
basic information
【Specifications (Partial)】 ■ Measurement Method: Gamma Ray Transmission Method ■ Detection Method: Scintillation Detector Method ■ Applicable Piping: 20A to 350A ■ Pressure-resistant Explosion-proof Type (Hydrogen Explosion-proof Type also available) ■ Density Measurement Range: 0 to 3000 kg/m3 (0.0 to 3.0 g/cm3) (Varies by pipe diameter) ■ Dustproof and Waterproof Structure Compliant with IP55 ■ Accumulation Time Variable Range: 0.5 to 36,000 sec *For more details, please download the PDF or feel free to contact us.
Price range
Delivery Time
Model number/Brand name
"PM-1000ExNC" [Not subject to regulations / Pressure-resistant explosion-proof]
Applications/Examples of results
【Applications】 ■Chemistry - Management of slurry concentration and density - Management of concentrations of toxic substances such as acids and alkalis - Management of blockage conditions - Density management of high-viscosity liquids *For more details, please download the PDF or feel free to contact us.