[Case Study of Solutions] Foreign Object Prevention. Reducing costs and creating a clean environment on-site.
Enclose the transport and assembly processes on the line with a booth, and install a precision air conditioning unit and a fan filter unit together to achieve a class below 10,000 and work temperature control.
【Proposed Solutions】 ■Traditional Method - Using spot coolers for workpiece cooling ■Issues - Foreign substances are blown onto the workpieces - The temperature of the blown air varies due to fluctuations in external temperatures, leading to changes in production conditions - High humidity in the blown air causes condensation, raising concerns about rust ■Ideal State (Desired Conditions) - Cleanliness in the transport and assembly processes is managed, preventing foreign substances from adhering - Temperature management is possible, stabilizing production conditions - No condensation occurs ■Aplist's Proposal - Enclose with a booth and select appropriate filter units to achieve a Class 10,000 environment - Use the PAU series precision air conditioning units to maintain a constant discharge temperature year-round - Supply dehumidified air using the PAU series precision air conditioning units to create a condensation-free environment ■Benefits - Resolution of foreign substance adhesion issues - Stabilization of production conditions - Resolution of condensation issues - Minimal costs with localized air conditioning - Additional significant energy savings - Additional reduction in management and disposal costs through non-fluorocarbon use - Additional capability to log production conditions (temperature and humidity data) *For more details, please refer to the PDF materials or related product catalogs, or feel free to contact us.
basic information
This is a case that is possible precisely because Apiste is involved in both environmental improvement and temperature control. Apiste also handles panel coolers for cooling, dehumidifying, and dust-proofing control panels, so we are skilled not only in temperature management but also in condensation prevention and foreign matter countermeasures. We will propose the optimal improvement methods tailored to each site, so please feel free to contact us. *For more details, please refer to the PDF materials or feel free to contact us. ↓ Inquiry format below ↓ ______________________ 1. Target space volume: (____㎥) ・ Undecided 2. Target temperature If decided: (____℃±____℃) If undecided: I would like to consult about the optimal temperature No temperature management needed 3. Target humidity If decided: ____%±____℃ If undecided: I would like to consult about the optimal humidity No humidity management needed 4. Target cleanliness If decided: Class ____ or below If undecided: I would like to consult about the optimal cleanliness No cleanliness management needed 5. Air conditioning method One-pass, internal circulation, undecided, unknown 6. Surrounding environment ____℃ ____%~ ____℃ ____%
Price range
Delivery Time
Applications/Examples of results
For more details, please refer to the PDF document or feel free to contact us.
Detailed information
catalog(5)
Download All CatalogsNews about this product(8)
-
【Amazing Dehumidification Ability!】Instant dry air supply possible with just the cooler! The "PAU-AZ2000SE-DR" can be used as a drive booth or dry air supply unit.
Precision air conditioning units enable energy-efficient and highly accurate management of temperature, humidity, and cleanliness through "local air conditioning," which conditions only limited spaces. This time, we would like to introduce the precision air conditioning unit specialized in dehumidification, the "PAU-AZ2000SE-DR"! The PAU-AZ2000SE-DR adopts Apiste's unique "MAX-DRY operation method," allowing for dehumidification of absolute moisture content by ▲65% using only the refrigeration cycle, which was previously considered difficult. For example, it can dehumidify intake air from 27°C and 70% humidity to 23°C and 30% humidity in a short time after starting operation. It can also be used for applications that previous precision air conditioning units could not accommodate, so if you are interested, please feel free to contact us. 【Application Examples】 - As a dry air conditioning unit when using hygroscopic materials! - As a drive booth for processes using organic solvents or powders! - As a dry air supply unit for the OA intake of air conditioning equipment!
-
[Information] Static electricity countermeasures! By managing humidity appropriately, you can prevent the occurrence of static electricity!
Static electricity causes various issues such as poor printing quality and equipment troubles. Static electricity occurs under several overlapping conditions, with "humidity" being the most important factor among them. This is a document about static electricity and humidity, considering the prevention of static electricity-related problems. In the related products section, we also introduce actual case studies of solutions. Please take a look.
-
[Case Study of Solution Proposal] Humidity management suppresses the adhesion of foreign substances due to static electricity!
This is a case that is possible precisely because Apiste specializes in both environmental improvement and precision air conditioning and temperature control. There was a customer in a factory producing precision parts who experienced a high number of defects due to foreign substances adhering to coiled metal before it was pressed, caused by static electricity. Apiste proposed a localized air conditioning system, stabilizing the temperature and humidity in the production area to create an environment less prone to static electricity. 【Solution Proposal Case】 ■ Conventional Method - Use of general air conditioning ■ Issues - Static electricity occurs in winter, causing foreign substances to adhere to the workpieces. - If the workpieces enter the press with foreign substances attached, they become defective products. ■ Ideal State - Suppression of static electricity generation, preventing foreign substances from adhering. ■ Apiste's Proposal - Installation of the PAU series precision air conditioning units along with booths and fan filter units to implement localized air conditioning. ■ Benefits - Control of humidity to suppress the generation of static electricity. - Stabilizing temperature and humidity only in the necessary areas minimizes initial costs. - Additionally, measures to prevent the intrusion of foreign substances are also realized.
-
Announcement of the Publication of the Comprehensive Catalog for Precision Air Conditioning Units: Introducing the latest catalog featuring all models of Apiste's precision air conditioning units, the "PAU Series"!
[Announcement of the Publication of the Comprehensive Catalog for Precision Air Conditioning Units] Precision air conditioning units are capable of creating and blowing air at set temperature and humidity levels. They boast a control accuracy of ±0.1°C and ±0.5%, and can maintain constant temperature and humidity, as well as cooling, heating, humidifying, and dehumidifying with a single unit. By combining with an optional fan filter unit, management of cleanliness can also be achieved. Recently, clean and highly precise temperature and humidity environments have been required in various fields such as manufacturing, inspection, testing, and research processes. At Apiste, we offer precision air conditioning units based on the concept of "local air conditioning & local cleanliness," which can flexibly respond to your desired constant temperature and humidity environment. Our catalog includes case studies, features, and specifications for each series, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents (Excerpt)] ■ Proposal for Local Air Conditioning ■ Applications ■ Lineup of Precision Air Conditioning Units ■ Specifications
-
[Case Study of Solution] Improved Data Instability of Electronic Scales by Introducing Local Air Conditioning!
This is a case that is possible precisely because Apiste specializes in both environmental improvement and precision air conditioning and temperature control. We proposed a localized air conditioning method to a customer who was using general air conditioning (standard air conditioners) but faced the issue of unstable measurement results from their electronic balance, resulting in stabilized measurement outcomes. 【Solution Proposal Example】 ■ Conventional Method - Use of general air conditioning ■ Issues - Temperature and humidity fluctuate with time and seasons, causing measurement results to vary ■ Ideal State - Measurement results remain stable throughout the year - Minimal initial costs ■ Apiste's Proposal - Installation of the PAU series precision air conditioning units and a booth to implement localized air conditioning ■ Benefits - Temperature and humidity around the electronic balance remain constant year-round - Reduction in measurement result fluctuations due to temperature and humidity - Initial costs kept to a minimum by only adjusting the temperature and humidity in the necessary space *For more details, please refer to the related product catalog or feel free to contact us.