news list
61~90 item / All 96 items
-
"Manga Material 'Is the Control Panel Getting Hot? - Factory Edition -' Now Available" Easy to read in manga format! An explanation of the effects of heat on control equipment!
We have released a document that explains heat countermeasures in an easy-to-understand manga format titled "Is Your Control Panel Getting Hot? - Factory Edition." Neglecting heat countermeasures for control panels can lead to system downtime due to heat-related issues, potentially stopping the production line. This document introduces coolers for control panels that can help solve such problems. It clearly explains how heat affects control equipment using graphs, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Trends in internal temperature of power control panels and external temperature in automobile manufacturers ■ Panel surface area and estimated internal temperature ■ Relationship between the lifespan of electrolytic capacitors and ambient temperature ■ Relationship between semiconductor failure rates and ambient temperature ■ Relationship between corrosion and relative temperature ■ Relationship between relative temperature and insulation characteristics
-
"Manga Material 'Save the Environmental Measuring Instruments! "Ken the Control Panel Cooler"' Now Available" Easy to read in manga format! An explanation of outdoor control panel coolers!
We have released a document titled "Save the Environmental Measuring Instruments! 'Ken the Control Panel Cooler'" that explains outdoor control panel coolers in an easy-to-understand manga format. Are there any of you who are worried about outdoor control panels causing heat-related issues? This document introduces Apiste's outdoor control panel cooler to design engineers facing the same concerns and summarizes the content leading to a solution in manga form. We clearly explain the features of the outdoor control panel cooler, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■Trouble cases of outdoor environmental measuring instruments ■Features of outdoor control panel coolers
-
[Manga Material "Saving the Factory Line! 'Control Panel Cooler Ken'" Now Available] Easy to read in manga format! Explaining heat-related troubles!
We have released a document titled "Save the Factory Line! 'Ken the Control Panel Cooler'" that explains heat troubles in an easy-to-understand manga format. Are there any concerns about heat troubles caused by the summer heat leading to the control panel stopping? This document explains the causes of heat generation inside the control panel, broken down by key points. We also introduce coolers for control panels to solve these issues, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■Step 1 Check the size ■Step 2 Look inside the panel
-
"Manga Material 'Improving the Oil Mist Environment! "Mist Collector Polar"' Now Available" Easy to read in manga format! An explanation about mist collectors!
We have published a document titled "Improving Oil Mist Environments! 'Mist Collector Polar'" which explains mist collectors in an easy-to-understand manga format. Are you struggling with oil mist not being fully collected due to filter clogging in your mist collector? In this document, we introduce the "GME Series" mist collector, which maintains its collection effectiveness even without long-term maintenance. We also explain the different types of mist collectors and the structural differences among them, so if you're interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Explanation of issues with filter-type and cyclone-type collectors ■ Features of disc-type collectors
-
"Manga Material 'Saving Hydraulic Systems! "Oil Chiller Bob"' Now Available" Easy to read in manga format! Explains the causes of hydraulic system failures!
We have released a document titled "Saving Hydraulic Systems! 'Oil Chiller Bob'" that explains hydraulic operation systems in an easy-to-understand manga format. Are there any of you who have introduced a hydraulic operation system but are facing issues such as the oil not cooling or the system going into emergency stop? This document explains the causes of these problems divided into four key points. We also introduce oil chillers for solving these issues, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Heat sources of hydraulic operation systems ■ Filters ■ Fins ■ Sealing properties
-
"Manga Material 'Manage Circulating Water Temperature with a Wide Range!' Now Available" Easy to read in manga format! An explanation of a precision chiller that can both heat and cool!
We have released a document that explains chillers in an easy-to-understand manga format titled "Manage Circulating Water Temperature with a Wide Range!" Are you struggling with whether to install two chillers to perform heating and cooling simultaneously? This document introduces the Apiste precision chiller "PCU-R series" to production technology personnel facing the same dilemma, summarizing the content leading to a solution in manga form. The features of the PCU-R series are explained clearly, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Examples of concerns when considering cooling equipment ■ Benefits of triple valve control
-
[Data "Hatena Magazine: Local Air Conditioning & Chiller Edition" Now Available] A clear explanation of temperature and humidity management and cooling equipment!
We have published a document explaining air conditioning and cooling water systems titled "Hatena Magazine: Local Air Conditioning & Chillers Edition." This document provides easy-to-understand explanations of basic knowledge about constant temperature rooms and clean rooms, as well as related information about cooling equipment, divided into 15 themes. Additionally, we introduce the differences between general air conditioning and local air conditioning, as well as how to select a chiller. If you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents (excerpt)] ■ What is a constant temperature room? ■ What is humidity? ■ How to select a chiller ■ What are the components of water?
-
[Data "Hatena Magazine Chiller Edition" Now Available] A clear explanation from pure water and ultra-pure water to the selection method for chillers!
We have published a document explaining the cooling water system titled "Hatena Magazine: Chiller Edition." The steps for selecting a chiller include determining the temperature of the circulating water and deciding on the cooling capacity and head. The document explains how to calculate cooling capacity and head using formulas and graphs. Additionally, we introduce methods for dealing with scale, plumbing issues, and basic knowledge about pumps. If you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ How to select a chiller ■ What are the components of water? ■ How to make pure water ■ What is industrial water?
-
Catalog for the non-fluorocarbon chiller 'PCU-NE Series,' which is not subject to the Fluorocarbon Emission Control Law, is now available.
【New Product! Non-Freon Chiller "PCU-NE Series" Catalog Released】 We have added a 1kW type to the lineup of the non-Freon chiller "PCU-NE Series." Along with this addition, we have also released the latest version of the catalog. If you are interested, please download the PDF from the related catalog below or feel free to contact us. ■ Features of the PCU-NE Series - Uses non-Freon refrigerant HFO-1234yf, exempt from the Freon Emission Control Law! - Industry first! Equipped with a drive recorder function and a time calendar function! - Standard Ethernet included to meet a wide range of communication needs!
-
[Data "Hatena Magazine Precision Air Conditioning Edition" Now Available] A clear explanation from constant temperature, dehumidification, and humidification to localized air conditioning!
We have published a document explaining air conditioning titled "Hatena Magazine: Precision Air Conditioning Edition." Air conditioning systems can be divided into general air conditioning and precision air conditioning. General air conditioning refers to home and commercial air conditioners, while precision air conditioning is used in clean rooms and constant temperature and humidity laboratories. This document introduces methods for achieving constant temperature and humidity, as well as basic knowledge regarding humidity and cleanliness. If you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents (excerpt)] ■ What is a constant temperature room? ■ What is humidity? ■ What is humidification? ■ What is dehumidification?
-
[Publication of "Hatena Magazine: Oil Chiller Edition" Now Available] A clear explanation from the basics of operating oil cooling to issues and solutions!
We have published a document explaining hydraulic oil titled "Hatena Magazine: Oil Chiller Edition." Hydraulic oil has an appropriate temperature depending on its characteristics and usage. If the temperature of the hydraulic oil rises, it can accelerate degradation and lead to unexpected troubles or equipment failures. This document introduces several types of hydraulic oil cooling devices, along with their respective issues and solutions. If you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■Basic knowledge of hydraulic oil cooling ■What is hydraulic pressure? ■What is oil? - Types of oil - ■What is oil? - Mineral oil - ■What is oil? - Industrial oil - ■What is a machine tool?
-
[Data "Hatena Magazine: Control Panel Cooler Edition" Now Available] Clearly explains the basics of heat countermeasures and the heat generation of various devices inside control panels!
We have published a document explaining heat countermeasures titled "Hatena Magazine: Control Panel Cooler Edition." Traditional heat countermeasures include panel fans, spot coolers, and air conditioning duct branches, but each has its own concerns, and it may not be said that any of them are perfect. This document introduces the benefits of using coolers for control panels as a heat countermeasure, as well as how to select a cooler for control panels. If you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Basic knowledge of heat countermeasures ■ List of heat generation by equipment inside control panels ■ What is a cooler for control panels? ■ What is a refrigeration circuit? ■ Collection of heat countermeasure applications for digital signage
-
[Data "Hatena Magazine Server Cooler Edition" Now Available] A clear explanation of the issues with traditional server heat management and the ideal solutions for server heat management!
We have published a document explaining heat management for servers titled "Hatena Magazine: Server Cooler Edition." Currently, about half of the individuals in office floors with server racks are potentially facing server heat issues. Additionally, over 38% of people reported using general floor air conditioning for heat management. This document also introduces the benefits of implementing server coolers that can specifically cool servers. If you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ What is server heat management? ■ Server rack cooler starter guide
-
Publication of the 'High-Performance Chiller Application Guide' for the steel and non-ferrous metal industry.
We have published an application guide for the steel and non-ferrous metal industries that leverages the features of our high-performance chiller, the "PCU-SL Series." This document introduces applications for the steel and non-ferrous metal industries using our high-performance chiller, the "PCU-SL Series." We will solve various conventional problems in applications such as cooling X-ray inspection equipment, plasma seam welding machines, and temperature management for laser processing machines with the high-performance chiller "PCU-SL Series"! We have presented this information clearly with illustrations, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Cooling of X-ray inspection equipment ■ Temperature management of laser processing machines ■ Cooling of plasma seam welding machines ■ Cooling of rolls/bearings/hydraulic units ■ Cooling of high-frequency induction heating devices
-
Publication of the 'High-Performance Chiller Application Guide' for the Paper and Corrugated Industry
We have published an application guide for the paper and cardboard industry that leverages the features of our high-performance chiller, the "PCU-SL Series." This document introduces applications for the paper and cardboard industry using our high-performance chiller, the "PCU-SL Series." We will solve various traditional problems in applications such as cooling X-ray thickness gauges, cooling cooling rolls, and temperature control in coating and gluing processes with the high-performance chiller "PCU-SL Series"! We have presented the information clearly with illustrations, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Temperature control in coating and gluing processes ■ Cooling of X-ray thickness gauges ■ Cooling of cooling rolls ■ Cooling of hydraulic units for pressure rolls, presses, and cylinders ■ Cooling and stabilization of BM gauges
-
High-Performance Chiller Application Guide for the Chemical and Resin Industry Now Available
We have published an application guide for the chemical and resin industry that leverages the features of our high-performance chiller, the "PCU-SL Series." This document introduces applications for the chemical and resin industry using our high-performance chiller, the "PCU-SL Series." We will solve various traditional problems in applications such as temperature management in sheet extrusion processes, coating and lamination processes, and temperature control of molds with the high-performance chiller "PCU-SL Series"! We have presented the information clearly with illustrations, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Temperature management in sheet extrusion processes ■ Temperature management in coating and lamination processes ■ Cooling of the water tank for extruders ■ Temperature control of molds ■ Cooling of stirrers and tanks
-
Materials for the Development and Evaluation Department 'High-Performance Chiller Application Guide' Now Available
We have published an application guide for the development and evaluation department that leverages the features of our high-performance chiller, the "PCU-SL Series." This document introduces applications for the development and evaluation department using our high-performance chiller, the "PCU-SL Series." We will solve various conventional problems in applications such as cooling for engine bench testers, battery charge and discharge devices, and utilities for environmental testing rooms and air handling units with the high-performance chiller "PCU-SL Series"! We have presented the information in an easy-to-understand manner, including illustrations, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Cooling for engine bench testers ■ Cooling for battery charge and discharge devices ■ Cooling for turbine and motor benches ■ Cooling for radiators and heat exchangers ■ Utilities for environmental testing rooms and air handling units
-
Publication of the document 'High-Performance Chiller Application Guide' for the Food and Pharmaceutical Industry
We have published an application guide for the food and pharmaceutical industries that leverages the features of our high-performance chiller, the "PCU-SL Series." This document introduces applications for the food and pharmaceutical industries using our high-performance chiller, the "PCU-SL Series." We will solve various conventional problems in applications such as cooling for vacuum drying, distillation, sterilization, degassing/defoaming equipment, as well as cooling for mixers and tanks, using the high-performance chiller "PCU-SL Series"! We have presented this information clearly with illustrations, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Cooling for vacuum drying, distillation, sterilization, degassing/defoaming equipment ■ Cooling for mixers and tanks ■ Cooling for thawing equipment transmitters ■ Cooling for laminators, heat sealers, and blisters ■ Cooling for grinders and kneaders
-
High-Performance Chiller Application Guide for the Semiconductor, Electronics, and Electrical Industry Now Available
We have published an application guide for the semiconductor, electronics, and electrical industries that leverages the features of our high-performance chiller, the "PCU-SL Series." This document introduces applications for the semiconductor, electronics, and electrical industries using our high-performance chiller, the "PCU-SL Series." We will solve various traditional problems in applications such as cooling for vacuum deposition equipment, sputtering and etching equipment, and laser oscillators with the high-performance chiller "PCU-SL Series"! We have presented the information clearly with illustrations, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Cooling for vacuum deposition equipment ■ Cooling for sputtering and etching equipment ■ Temperature conditions for aging test equipment for semiconductor devices ■ Cooling for laser oscillators ■ Temperature control for chemical solution tanks
-
【New Catalog for High-Performance Filter Type Mist Collector "GME-F Series"】 Achieve low maintenance even with a filter type! This high airflow model can accommodate various applications.
Sustain high collection efficiency without frequent filter maintenance! Introducing the high-performance filter mist collector "GME-F Series"! ■ High Airflow Model This is a high airflow model that offers seven times the airflow compared to conventional models. (Compared to GME-S400) It can be used in various settings where a large airflow is required from a single mist collector, such as open-type processing machines and piping installations with many branches. ■ Long-term Maintenance-Free The smoke catch filter uses a cross-flow method where the direction of oil discharge is perpendicular to the airflow, making it easier for the aggregated oil mist to be expelled. Therefore, you can maintain high collection efficiency for an extended period without the need for filter maintenance! Additionally, it is composed of ultra-fine glass fiber and polyester fibers, allowing it to capture even the tiny oil mist particles that the mist collector alone could not collect. ■ Preventive Maintenance with Differential Pressure System It comes standard with a differential pressure gauge that allows you to check the timing for filter replacement numerically. Since the clogging level can be confirmed with numbers, you don't have to worry about missing the right time to replace the filter. If you are interested, please feel free to contact us.
-
【New Catalog for Non-Freon Oil Chiller "VSC-N Series"】This is the industry's first oil chiller that uses non-Freon refrigerant! It achieves high-precision oil temperature management of ±0.1℃ with hot gas bypass control and is compatible with IoT.
Introducing the non-fluorocarbon oil chiller "VSC-N Series," which eliminates fluorocarbon management costs while achieving high-precision oil temperature control! ■ Adoption of Non-Fluorocarbon Refrigerant With the revision of the Fluorocarbon Emission Control Law on April 1, 2020, regulations on fluorocarbons have become increasingly strict. The VSC-N Series, which uses the non-fluorocarbon refrigerant HFO-1234yf, is exempt from the Fluorocarbon Emission Control Law, allowing you to eliminate cost burdens associated with fluorocarbons. ■ High-Precision Oil Temperature Control Equipped with hot gas bypass control via a heating valve, the cooling capacity can be varied according to the heat generation on the cooling target side, achieving high-precision oil temperature management within ±0.1°C. It can be safely used for spindle cooling in machine tools where control precision is required. ■ IoT Compatible Standard equipped with read/write compatible external communication Modbus/RTU communication (RS-232C). In addition to data reading, setting changes can also be made from the touch panel or PLC. If you are interested, please feel free to contact us.
-
【New Catalog for Non-Freon Chiller "PCU-NE Series"】Utilizing the non-Freon refrigerant HFO-1234yf, it is not subject to the Freon Emission Control Law! Furthermore, it is a new era chiller equipped with the industry's first drive recorder function and time calendar function.
Introducing the new era of non-freon chillers, the "PCU-NE Series," designed with consideration for the Earth's environment and user burden! ■ Adoption of Non-Freon Refrigerants With the revision of the Freon Emission Control Law on April 1, 2020, regulations on freon have become increasingly strict. The PCU-NE series, which uses non-freon refrigerants, is exempt from the Freon Emission Control Law, eliminating the cost burden associated with freon. ■ Equipped with Drive Recorder and Time Calendar Functions The chiller records data such as circulating water outlet temperature, circulating water set temperature, operating hours, and error occurrence dates, allowing users to review the recorded history. This enables better understanding of the chiller's status and troubleshooting, significantly reducing response time in case of any issues. ■ IoT Compatibility As the demand for IoT in manufacturing sites increases, the PCU-NE series comes standard with Ethernet connectivity. It supports external communication via Modbus/TCP, as well as MC protocol and socket communication methods. If you are interested, please feel free to contact us.
-
[New Chiller Catalog Now Available] Introducing the Apiste Chiller lineup!
Introducing our comprehensive lineup of chillers that meet all your needs! ■ Non-Freon Chiller PCU-NE Series - Uses non-Freon refrigerant R1234yf, exempt from the Freon emission suppression law - Industry-first drive recorder and time calendar function ■ Wide Range Chiller PCU-R Series - Wide range of -10 to 80℃ - Class-leading accuracy of ±0.05℃ ■ High Durability Chiller PCU-SL Series - Does not stop even in high-temperature environments - Usable outdoors
-
"New Catalog for Filterless & Energy-Saving Non-Freon Control Panel Cooler 'ENC-GR-Pro Series' Now Available" Naturally, it uses non-Freon refrigerant, and its filterless design minimizes clogging, reducing maintenance efforts! It is also equipped with a uniquely developed inverter, achieving energy savings.
Introducing the "ENC-GR-Pro Series" control panel cooler, equipped with new features that not only eliminate refrigerant management costs but also further reduce the burden on customers! ■ Low Maintenance The ENC-GR-Pro series utilizes a finless condenser. Since there are no areas prone to clogging, filters are unnecessary, significantly reducing maintenance costs and labor. ■ Energy Saving & Powerful Cooling With control via a uniquely developed inverter, the system operates according to the load rate, achieving up to 55% energy savings compared to conventional models. (This applies to the ENC-GR1500L-Pro model.) Furthermore, unlike traditional coolers that stop cooling operations in high-temperature environments due to protective functions, the ENC-GR-Pro series can continue cooling operations. ■ IoT Compatibility For the first time in control panel coolers, external communication with read/write capability and Modbus/RTU communication (RS-485) is standard. Up to 32 units can be connected, allowing for temperature monitoring and setting changes from a touch panel or PLC. If you are interested, please feel free to contact us.
-
【Technical Document "Protecting Health with Dust Control! vol.4" Now Available】A clear explanation of regulations regarding dust!
We have released a document titled "Protecting Health through Dust Control! vol.4," which explains the regulations related to dust control. The regulations related to dust control include the Industrial Safety and Health Act and the Dust Hazard Prevention Regulations. Employers need to protect the health of workers and ensure a comfortable working environment through dust control measures. The document not only details the regulations but also introduces provisions regarding equipment and management. If you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents (excerpt)] ■ Industrial Safety and Health Act / Dust Hazard Prevention Regulations ■ Work subject to the Dust Hazard Prevention Regulations ■ Provisions regarding equipment and management ■ High-performance dust collectors "GDE Series"
-
【Technical Document "Protecting Health with Dust Control! vol.3" Now Available】A clear explanation of how to manage dust-related work!
We have released a document titled "Protecting Health with Dust Control! vol.3," which explains the management and inspection of dust work. When workers are required to work in environments where they may be exposed to dust, employers are obligated to provide special training to the workers. Additionally, it is stipulated that regular inspections of exhaust and ventilation systems, as well as dust concentration measurements, must be conducted. The document introduces the content of inspections and cleaning methods as dust control measures, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents (excerpt)] ■ Special training for dust work ■ Inspection of exhaust and ventilation systems ■ Inspection of equipment that seals the source ■ Inspection of sprinkling systems, etc. ■ What is important is daily organization and cleaning.
-
【Technical Document "Protecting Health with Dust Control! vol.2" Now Available】A clear explanation of dust control measures for disease prevention!
We have published a document titled "Protecting Health with Dust Control! vol.2," which explains methods for controlling dust. To prevent diseases caused by dust, it is essential to minimize dust generation as much as possible. Effective measures include reviewing work methods and raw materials, as well as reassessing the structure and equipment of buildings. The document introduces other specific countermeasures, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. 【Contents (excerpt)】 ■ How to reduce the generation of "dust"? - Review work methods and raw materials - Reassess the structure and layout of buildings and equipment - Seal off sources of "dust" to implement countermeasures - Suppress dust dispersion through methods such as sprinkling water
-
【Technical Document "Protecting Health with Dust Control! vol.1" Now Available】A clear explanation of the health issues caused by dust!
We have published a document titled "Protecting Health with Dust Control! vol.1," which explains health disorders caused by dust. Dust refers to the general term for solid particulate matter suspended in the atmosphere, including fumes generated during welding operations. Various work processes exist on-site, and the materials handled are diverse, resulting in the generation of several types of dust. These dust particles can enter the body through inhalation via the mouth or nose or through contact, leading to harmful health effects. The document introduces the substances that cause health disorders and representative workplaces where they occur. If you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents (excerpt)] ■ Dust-like solid particles floating in the atmosphere ■ Health-hazardous "dust" ■ Chemical composition of "dust" ■ Particle size of "dust" ■ Inhalation amount of "dust"
-
The new catalog for the non-Freon precision air conditioning unit "PAU-GR Series," capable of high-precision air conditioning management, has arrived. It uses the non-Freon refrigerant HFO-1234yf, which is not subject to the Freon emission control law! By utilizing "local air conditioning" that only conditions the necessary space, it achieves high-precision management of temperature, humidity, and cleanliness.
【New Product! Non-Freon Precision Air Conditioning Unit "PAU-GR Series" Catalog Released】 We are pleased to announce the launch of our new product, the Non-Freon Precision Air Conditioning Unit "PAU-GR Series." Precision air conditioning units significantly reduce installation, construction, and electricity costs compared to conventional air conditioning by providing "local air conditioning" that only conditions the necessary space. 【Features of Non-Freon Precision Air Conditioning Unit PAU-GR Series】 ■ Temperature and Humidity Control With the "local air conditioning" concept, it is possible to achieve extremely precise temperature control of ±0.1°C and humidity control of ±0.5% RH. ■ Adoption of Non-Freon Refrigerant The PAU-GR series, which uses non-freon refrigerant, is not subject to the Freon Emission Control Law, eliminating the cost burden associated with freon. ■ Energy Saving Achieved ultra-energy savings through complete heater-less operation and inverter control. If you are interested, please download the PDF from the related catalog below or feel free to contact us.
-
【Technical Document "Cutting Oil Book vol.5" Now Available】A clear explanation of the health effects of cutting oils and measures against oil mist!
We have published a document titled "Cutting Oil Book vol.5," which explains the health hazards caused by oil mist and the measures to address them. During machining processes, the oil agents that scatter can not only dirty floors and walls but also affect the health of those handling the oil agents or performing machining tasks due to contact with the oil agents. The document introduces specific measures to prevent health hazards, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents (excerpt)] ■Handle with care! Potential health impacts… - Deterioration of the working environment due to oil agent scattering - Preventing skin contact - Protecting eyes from scattering - Preventing odors and inhalation