セントラル科学 Official site

Sievers TOC analyzer suitable for the pharmaceutical and semiconductor industries.

Ultra-pure water for semiconductors, pharmaceutical water, tap water, wastewater and environmental water, and boiler water are all supported!

Organic matter contained in household and factory wastewater serves as food for aquatic organisms. While BOD and COD represent the amount of oxygen consumed for the decomposition of organic matter, TOC is a water pollution indicator that expresses the absolute amount of carbon contained in organic matter. TOC measurements are conducted across a wide range of industrial fields, from wastewater and environmental water to boiler water, ultra-pure water for semiconductors, and pharmaceutical manufacturing water. There are three series categorized by application fields, each offering three types: lab-type, portable-type, and online-type. ■ M9 Series ... For the pharmaceutical industry (compliant with 3 agencies), features Data Guard function compatible with 21 CFR part 11. ■ M9e Series ... For the semiconductor industry. ■ M5310C Series ... For the water supply sector, with a custom multi-point calibration protocol that complies with notification laws, and capable of meeting the requirements of the "Guidelines for the Validation of Water Quality Testing Methods." *For details, please request materials or view the PDF data available for download.

basic information

Main equipment specifications of the TOC analyzer M9/M9e series (*Validation protocol built-in is only for the M9 series) Measurement method: Wet UV oxidation + gas permeable membrane conductivity measurement method Measurement range: (Normal) 0.03 ppb to 50 ppm, (Turbo mode) 0.2 to 10 ppm Measurement interval: (Normal) 2 minutes, (Turbo mode) 4 seconds Inorganic carbon removal device: Can be installed inside the main unit *For more details, please refer to the PDF or feel free to contact us.

Price information

Please contact us.

Delivery Time

Model number/Brand name

Sievers TOC Analyzer M9/M9e/M5310C

Applications/Examples of results

M9 Series... for the pharmaceutical industry, M9e Series... for the semiconductor industry M5310C Series... for the drinking water sector *For more details, please refer to the catalog or feel free to contact us.

Related Videos

Line up(3)

Model number overview
M9 Measurement range: 0.03ppb to 50ppm
M9e Measurement range: 0.03ppb to 50ppm
M5310C Measurement range: 4ppb to 50ppm

catalog(88)

Download All Catalogs

TOC Analyzer for Pharmaceuticals Sievers M9

PRODUCT

TOC meter for cleaning validation

PRODUCT

Pharmaceutical Water/Cleaning Validation Sievers M9 Laboratory Type

PRODUCT

Purified Water/Injection Water Management Sievers TOC Meter Online/Portable Type

PRODUCT

Performance comparison of TOC analyzers Sievers 900 and M9 models.

TECHNICAL

Water quality monitoring of ultrapure water production systems for semiconductors (TOC & boron)

TECHNICAL

Evaluation of manufacturing equipment cleaning by TOC

TECHNICAL

Utilization of TOC monitoring for food/beverage manufacturers

TECHNICAL

Water quality management and leak detection for boiler water and cooling water using TOC.

TECHNICAL

Optimization Tool for Water Treatment Processes for Water Utilities

TECHNICAL

Purity management of chemical substances by TOC

TECHNICAL

Swab TOC recovery rate of the compound in the worst-case scenario (feasibility test)

APPLICATION_NOTE

Differences in TOC measurement values due to sampling methods

APPLICATION_NOTE

Reduction of boiler operating costs through TOC calculation

APPLICATION_NOTE

TOC helps to protect the product quality of spice manufacturers.

APPLICATION_NOTE

Sievers M Series Turbo Mode for Rapid Liquid Leak Detection

APPLICATION_NOTE

TOC recovery rate of gluten using Sievers M9

APPLICATION_NOTE

Food and beverage manufacturers improve production efficiency and quality control through TOC analysis of cleaning cycles.

APPLICATION_NOTE

Solving water treatment challenges in power generation facilities through TOC monitoring.

APPLICATION_NOTE

Early detection of ethylene glycol leaks in steam condensate at power plants.

APPLICATION_NOTE

Monitoring of cooling wastewater using TOC measurement.

APPLICATION_NOTE

Online monitoring of TOC and boron for the generation of high-purity steam and efficient power generation.

APPLICATION_NOTE

Protection of RO membranes using an online TOC meter by Tampa Electronic Pork Power Plant.

APPLICATION_NOTE

Recovery rate of volatile compounds by TOC measurement

APPLICATION_NOTE

Monitoring of organic matter in the condensate of boiler equipment using TOC in a European animal feed factory.

APPLICATION_NOTE

Water Quality Monitoring at Oil Refineries: The Impact of Real-Time Data on Compliance with Quality Regulations and Reuse

TECHNICAL

Condensate monitoring for leak detection and equipment protection using Sievers TOC measurement.

APPLICATION_NOTE

Sievers Brown TOC Vial

APPLICATION_NOTE

Sievers TOC Vial Style_Infographic

PRODUCT

Monitoring of organic substances in industrial water using the Sievers TOC analyzer.

TECHNICAL

Paradigm shift in the monitoring methods of organic matter in drainage.

APPLICATION_NOTE

Real-time release through online cleaning validation using total organic carbon, inorganic carbon, and conductivity data.

APPLICATION_NOTE

TOC recovery rate of complex compounds: cleaning agents

APPLICATION_NOTE

Comparison of TOC Cleaning Validation Swab Kits.

APPLICATION_NOTE

TOC measurement of 0.2M sodium hydroxide using the Sievers M9 type.

APPLICATION_NOTE

TOC measurement of 0.2M potassium hydroxide using the Sievers M9 type.

APPLICATION_NOTE

Simultaneous measurement of TOC and conductivity to analyze non-conductive organic substances in cleaning agents.

APPLICATION_NOTE

TOC recovery rate using STERIS Life Sciences' cleaning agent_Sievers M9 type

APPLICATION_NOTE

Validation of TOC Method for Cleaning Validation in the Pharmaceutical Industry

APPLICATION_NOTE

Calculation of Maximum Allowable Carryover (MAC) in Cleaning Validation

APPLICATION_NOTE

Sievers Validation Support Package for Cleaning Validation

TECHNICAL

PAT Application: At-line TOC measurement for cleaning validation and product changeover.

APPLICATION_NOTE

Reduction of cleaning validation and product changeover costs by 92% through in-line TOC measurement.

APPLICATION_NOTE

Cleaning validation: Verifying the performance of the cleaning process.

APPLICATION_NOTE

Evaluation of the validity of cleaning standards based on engineering capability index

APPLICATION_NOTE

Analysis method for cleaning validation

APPLICATION_NOTE

Detection of TOC and conductivity of CIP-100 using the Sievers M series.

APPLICATION_NOTE

TOC recovery rate of insoluble and difficult-to-decompose compounds

APPLICATION_NOTE

Cost comparison of TOC and HPLC (using TOC analyzers for cleaning validation)

APPLICATION_NOTE

Sievers M9 type used for lab_atline_online_cleaning_validation

APPLICATION_NOTE

Real-time low-flow cleaning efficacy evaluation of pharmaceuticals using TOC and conductivity.

APPLICATION_NOTE

Cleaning evaluation: Microbial TOC recovery rate and linearity

APPLICATION_NOTE

Best Practices for Measuring Conductivity of Sievers M9 Type in Pharmaceutical Water

APPLICATION_NOTE

Measurement of conductivity and TOC using Sievers M9.

APPLICATION_NOTE

Sievers M9 Conductivity Measurement USP 645 Improvement of Stage 1 Robustness and Best Practices

APPLICATION_NOTE

Conductivity & TOC dual-use (DUCT) vial

PRODUCT

Performance and Stability of DUCT Vials

APPLICATION_NOTE

TOC & Conductivity Sample Storage Container

APPLICATION_NOTE

Conductivity & TOC Sampling Standard Operating Procedure

MANUAL

Simultaneous measurement of TOC and conductivity for efficiency improvement and cost reduction.

APPLICATION_NOTE

Linearity of conductivity in low concentration range - TOC measurement Sievers M9 sample conductivity measurement function

APPLICATION_NOTE

Suitability of Conductivity Measurement for M9_EP Monograph_EP2.2.38_USP645

APPLICATION_NOTE

Simultaneous measurement of conductivity USP Stage 1 and TOC of pharmaceutical water in the lab.

APPLICATION_NOTE

Screening of USP 661.1 plastic packaging materials using the TOC meter Sievers M9 type.

APPLICATION_NOTE

TOC analysis of leachables in USP661 (Plastic Packaging Systems and Materials).

APPLICATION_NOTE

Management and Maintenance of Pharmaceutical Water Systems Using the TOC Meter Sievers M9 Portable Type

APPLICATION_NOTE

Cost Savings in Water Treatment through Raw Water Variation Monitoring: Process Management Using TOC at Water Treatment Plants

APPLICATION_NOTE

Improvement of water treatment reliability through control of coagulant dosage using TOC.

APPLICATION_NOTE

Comparison of TOC and UV Absorbance in Water Treatment

APPLICATION_NOTE

TOC analysis as an optimization tool for water treatment processes at water purification plants.

APPLICATION_NOTE

Optimization of the MIEX system using TOC.

APPLICATION_NOTE

Enhancement of process control for ion exchange systems for NOM and DBP management.

APPLICATION_NOTE

Optimization of Eutrophication Prevention through TOC Analysis

APPLICATION_NOTE

Optimization of Eutrophication Prevention through TOC Analysis

APPLICATION_NOTE

Process optimization and regulatory compliance using TOC at a water treatment plant: Helena, Montana, USA.

APPLICATION_NOTE

Utilization of Organic Matter Monitoring in Direct Drinking Water Reuse Plants: A Solution to Water Shortages Due to Droughts.

APPLICATION_NOTE

Plans for the Future: Water Quality Protection Using Granular Activated Carbon Treatment and TOC Analysis

APPLICATION_NOTE

Reliable organic monitoring for water reuse.

APPLICATION_NOTE

Quality assurance of cooling water using M5310C.

APPLICATION_NOTE

TOC Measurement Support Tool

PRODUCT

Sievers Products Standard Solutions & Consumables Catalog

PRODUCT

【Water/Environmental Water】TOC Analyzer Sievers M5310C

PRODUCT

Sievers TOC Sensor CheckPoint Pharma

PRODUCT

Comparison of TOC measurements in the cleaning validation of protein samples.

APPLICATION_NOTE

TOC Analyzer Sievers M9e for the Semiconductor/Electronics Industry

PRODUCT

Sievers TOC Sensor CheckPoint e

PRODUCT

Conductivity Bridging Study: From Laboratory Conductivity Meter to Sievers M9 Type

APPLICATION_NOTE

Recommended products

Distributors