Online TOC Analyzer Sievers M500 Model

An online TOC analyzer that adopts the "gas permeable membrane conductivity measurement technique" in accordance with the Japanese Pharmacopoeia General Test Method <2.59 Organic Carbon Test Method>.

The online TOC analyzer Sievers M500 is the third generation of online TOC analyzers that has developed Sievers' long-standing reagent-free gas permeable membrane conductivity measurement technology. While inheriting the conventional "accuracy," "reproducibility," and "stability," it has achieved rapid measurement and enhanced data management functions. 【Unique technology compliant with the Japanese Pharmacopoeia】 - Complies with the Japanese Pharmacopoeia General Test Method <2.59 Organic Carbon Test> - Complies with various national pharmacopoeias (USP <643>, EP 2.2.44) - Measures by separating carbon dioxide: gas permeable membrane conductivity measurement method - Calibration using potassium hydrogen phthalate - Detects sodium dodecylbenzenesulfonate with a recovery rate of over 90% 【High performance & high functionality】 - Real-time measurement at 3-minute intervals - Flexible sampling functions - Abundant system protocols - Data integrity compliant with 21 CFR Part 11

Central Science Corporation HP

basic information

【TOC】 Measurement Principle: Ultraviolet Oxidation + Gas Permeable Membrane Conductivity Measurement Method Measurement Range: 0.03 to 2,500 ppb TOC Detection Limit: 0.03 ppb Quantification Limit: 0.1 ppb Accuracy: ±5% of the measured value or ±0.1 ppb, whichever is larger Reproducibility: ±1% of the measured value or ±0.03 ppb, whichever is larger 【Conductivity】 Measurement Range: 0.01 to 800 μS/cm Accuracy: ±1% or ±0.005 μS/cm, whichever is larger Reproducibility: Within 1.0%

Price range

Delivery Time

Model number/Brand name

Sievers M500

Applications/Examples of results

**Real-Time Testing of Pharmaceutical Water** Real-time testing of TOC and conductivity using Process Analytical Technology (PAT) enables a better understanding and control of the pharmaceutical water system, improving quality and productivity. PAT utilizes real-time measurement data to design, analyze, and manage processes, ensuring product quality. To maximize the benefits of PAT, validation of the analytical method for TOC meters is necessary. The Sievers M500 provides documentation and standard solutions to support the implementation of analytical method validation. Adopting real-time testing for pharmaceutical water offers the following benefits: - Reduction of costs/resources/contamination/lab errors/data delays associated with traditional lab analysis - Real-time detection of out-of-specification and out-of-trend test results - Root cause analysis utilizing TOC/inorganic carbon/conductivity - Technology transfer from lab testing to online testing using Sievers TOC measurement technology.

Detailed information

Related Videos

catalog(12)

Download All Catalogs

Online TOC Analyzer Sievers M500

PRODUCT

Real-time TOC testing of PAT and pharmaceutical water

TECHNICAL

TOC Analyzer Sievers M500 compliance with 21 CFR Part 11 and data integrity

APPLICATION_NOTE

Real-time test validation support package for pharmaceutical water.

APPLICATION_NOTE

Sievers TOC Sensor CheckPoint Pharma

PRODUCT

Sievers TOC Sensor CheckPoint e

PRODUCT

Bridging study for RTT process validation

APPLICATION_NOTE

Best practices for risk assessment applicable to RTT.

APPLICATION_NOTE

Best Practices for Out of Specification (OOS) Investigation Results

APPLICATION_NOTE

Sievers TOC Measurement Data Management Software DataShare Elite Software

PRODUCT

TOC Analyzer for Pharmaceuticals Sievers M9

PRODUCT

Maintaining data integrity during the transfer to RTT.

APPLICATION_NOTE

News about this product(1)

Distributors

Recommended products