[Example] Structural Strength Analysis of a Pump 'AIFEM'
One of the investigations into the impact of peak water pressure on structures! A case study analyzing the strength of the pump body.
We would like to introduce a case study of static analysis of a pump structure using the general-purpose finite element analysis software "AIFEM." The pump model being analyzed consists of two components: the main body and the cover, which are connected by a flange. By investigating the pressure distribution of the pump, it is possible to confirm the mechanical properties of the structure and quickly evaluate the design in question. 【Analysis Conditions】 ■ Material - Young's Modulus: 205000 [MPa] ■ Material - Poisson's Ratio: 0.28 ■ Load Condition: C surface 4.5 [MPa] ■ Component Joint: D surface, E surface ■ Constraint Conditions: A surface, B surface *For more details, please download the PDF or feel free to contact us.
basic information
【Analysis Results】 ■Displacement (mm) ・AIFEM: 0.1597 ・Reference Result: 0.1597 ■Strength (MPa) ・AIFEM: 506.4 ・Reference Result: 506.4 *For more details, please download the PDF or feel free to contact us.