catalog
Please complete the inquiry form to access eBook details
-
Proposal for CALGAVIN's 'hiTRAN' Heat Exchanger Heat Transfer Enhancement Element
Contact this catalog
-
CALGAVIN's "hiTRAN" heat transfer enhancement element / Mechanism for dirt reduction
Contact this catalog
-
-
-
Case Study 2: Decompression Distillation Tower Reboiler (Achieving a 40% Increase in Processing Capacity and a 20% Safety Margin)
Contact this catalog
-
Case Study 3: Improvement of P-Xylene Feed/Effluent Vaporizer (Improvement of Heat Transfer Coefficient on the Pipe Side and Achievement of Increased Production)
Contact this catalog
-
Case Study 4: Improvement of Heat Transfer Capacity in LNG Vaporizers (Achieving Suppression of Film Boiling and Uniform Fluid Distribution)
Contact this catalog
-
Case Study 5: Heat Transfer Enhancement of Triethylene Glycol Intermediate Heat Exchanger for Gas Dehydration (Minimizing Tube Bundle Size and Cost)
Contact this catalog
-
Case Study 6: Heavy Wax Fraction Cooler (Reduction of Contamination and 50% Reduction in Required Heat Transfer Area)
Contact this catalog
-
Case Study 7: Decompression Residual Oil/Crude Oil Preheating Intermediate Heat Exchanger (Achieving Heat Transfer Enhancement and Minimization of Fouling)
Contact this catalog
-
Case Study 8: LNG Condensate Stabilizer Reboiler Capacity Enhancement (Improvement of Liquid Distribution and Reduction of Film Boiling)
Contact this catalog
-
Case Study 9: Heavy Cycle Gas Oil Cooler (Achieved 80% Reduction in Heat Transfer Area, Stable Performance, and No Generation of Adhesive Residues)
Contact this catalog
-
Case Study 15: Carbon Black Manufacturing Equipment / Tar Residue Oil Heater (Achieved over 25 years of operational performance)
Contact this catalog
-
Case Study 19: Texas Tower Existing Renovation (15% Capacity Increase Due to Heat Transfer Enhancement Body on the Pipe Side)
Contact this catalog
-
Case Study 20: Heat Exchanger for FPSO/Oil-Water Separation Plant (Reduction in the Number of Heat Exchangers, Cost Reduction of Equipment, Achievement of Fouling Prevention)
Contact this catalog
-
Case Study 21: Hydrogen Treatment Equipment Feed/Effluent Heat Exchanger (Achieving Increased Capacity and Significant Fuel Reduction)
Contact this catalog
-
Case Study 22: Comparison of hiTRAN Heat Transfer Enhancement Elements for Multi-Tube Heat Exchangers
Contact this catalog
-
Case Study 23: Application of hiTRAN Heat Transfer Enhancement Elements to Air Fin Coolers
Contact this catalog
-
-
-
-
-
-
-
Acquisition of Environmental Product Declaration Certification / Presezzi Magnetic Heater
Contact this catalog
-
-
-
-
-