CALGAVIN Multi-tube Heat Exchanger Heat Transfer Enhancement 'hiTRAN' Catalog

Increase and improve the capacity of heat exchangers, reduce fouling inside the tubes! A group of experts dedicated to solving various issues related to heat exchangers. Support from Japanese professionals who are well-versed in processes and heat exchangers!

◇ What is "hiTRAN"? 1. Wire elements intricately woven are inserted into the tubes of the heat exchanger. 2. Various wire materials such as SUS and copper can be used. 3. Compatible diameters: φ6 to φ150mm. 4. Applicable to both "existing" and "new" heat exchangers. 5. Appropriate shapes and densities are selected according to specification conditions. ◇ What are the benefits of "hiTRAN"? 1. Miniaturization of new heat exchangers (e.g., from 4 to 1 pass) ⇒ Reduction in initial costs! 2. Recovery of capacity in existing heat exchangers ⇒ Reduction in running costs! 3. Prevention and reduction of dirt inside the heat exchanger tubes ⇒ Reduction in maintenance costs and shutdown time! 4. Improvement of plant operational capacity ⇒ Reduction in utility costs!

Here is the CALGAVIN company's homepage.

basic information

◇ What is CALGAVIN? 1. A "specialist group for solving heat exchanger-related issues" established in the UK in 1980. 2. Over 30 years of experience and achievements worldwide in collaboration with universities and research institutions. ◇ What is the process for inserting "hiTRAN"? 1. Confirmation of processes and specifications for heat exchangers, and meetings. 2. Performance comparison calculations before and during the insertion of hiTRAN. 3. Contracting, arranging hiTRAN, delivery, and insertion of hiTRAN into the heat exchanger. * Please perform the insertion of hiTRAN yourself. Insertion guidance (separate contract) is also available.

Price range

Delivery Time

Model number/Brand name

hiTRAN Heat Transfer Enhancement Element

Applications/Examples of results

◇ What equipment can "hiTRAN" be applied to? Shell and tube heat exchangers, heaters, coolers, condensers, evaporators, reboilers, reactors, preheaters, evaporators, recuperators, etc. ◇ What industries can "hiTRAN" be applied to? Steel and non-ferrous industries, oil exploration and production, oil refining, petrochemicals, organic and inorganic chemicals, gas production, transportation, and processing, specialty and precision chemicals.

Detailed information

Related Videos

catalog(19)

Download All Catalogs

CALGAVIN's "hiTRAN" Catalog

PRODUCT

Proposal for CALGAVIN's 'hiTRAN' Heat Exchanger Heat Transfer Enhancement Element

TECHNICAL

Case Study 1: Performance Improvement of Hysomer Feed/Effluent Heat Exchanger

TECHNICAL

Case Study 2: Decompression Distillation Tower Reboiler (Achieving a 40% Increase in Processing Capacity and a 20% Safety Margin)

TECHNICAL

Case Study 3: Improvement of P-Xylene Feed/Effluent Vaporizer (Improvement of Heat Transfer Coefficient on the Pipe Side and Achievement of Increased Production)

TECHNICAL

Case Study 4: Improvement of Heat Transfer Capacity in LNG Vaporizers (Achieving Suppression of Film Boiling and Uniform Fluid Distribution)

TECHNICAL

Case Study 5: Heat Transfer Enhancement of Triethylene Glycol Intermediate Heat Exchanger for Gas Dehydration (Minimizing Tube Bundle Size and Cost)

TECHNICAL

Case Study 6: Heavy Wax Fraction Cooler (Reduction of Contamination and 50% Reduction in Required Heat Transfer Area)

TECHNICAL

Case Study 7: Decompression Residual Oil/Crude Oil Preheating Intermediate Heat Exchanger (Achieving Heat Transfer Enhancement and Minimization of Fouling)

TECHNICAL

Case Study 8: LNG Condensate Stabilizer Reboiler Capacity Enhancement (Improvement of Liquid Distribution and Reduction of Film Boiling)

TECHNICAL

Case Study 9: Heavy Cycle Gas Oil Cooler (Achieved 80% Reduction in Heat Transfer Area, Stable Performance, and No Generation of Adhesive Residues)

TECHNICAL

Case Study 15: Carbon Black Manufacturing Equipment / Tar Residue Oil Heater (Achieved over 25 years of operational performance)

TECHNICAL

Case Study 19: Texas Tower Existing Renovation (15% Capacity Increase Due to Heat Transfer Enhancement Body on the Pipe Side)

TECHNICAL

Case Study 20: Heat Exchanger for FPSO/Oil-Water Separation Plant (Reduction in the Number of Heat Exchangers, Cost Reduction of Equipment, Achievement of Fouling Prevention)

TECHNICAL

Case Study 21: Hydrogen Treatment Equipment Feed/Effluent Heat Exchanger (Achieving Increased Capacity and Significant Fuel Reduction)

TECHNICAL

Case Study 22: Comparison of hiTRAN Heat Transfer Enhancement Elements for Multi-Tube Heat Exchangers

TECHNICAL

Case Study 23: Application of hiTRAN Heat Transfer Enhancement Elements to Air Fin Coolers

TECHNICAL

CALGAVIN's "hiTRAN" heat transfer enhancement element / Mechanism for dirt reduction

TECHNICAL

News about this product(1)

Recommended products

Distributors