PIAB <Case Study> Reduction of Compressed Air Consumption by Multi-Stage Ejectors
Realization of reduced compressed air consumption by replacing with a multi-stage ejector!
Replacement with Piab's inline ejector series "piINLINE MINI Xi" Background: The consumption of compressed air has increased, necessitating the purchase and installation of a new compressor. Solution: Replacing single ejectors with multi-stage ejectors to reduce compressed air consumption by over 50%. Effect: Reduces compressed air consumption by over 50% per ejector. (Piab Japan Co., Ltd.)
basic information
Compressed air consumption: 24 NL/min @ 0.45 MPa Maximum intake volume: 45 NL/min Maximum achievable vacuum pressure: -95 kPa
Price range
Delivery Time
Model number/Brand name
piINLINE MINI
Applications/Examples of results
Press parts manufacturing line