Dissimilar Metal Contact Corrosion Test [Silicoroy Technology Handbook]
Evaluation of individual test specimens! Publication of test results for "Silicoloy A2-OAG" and "SUS440" among others.
This document presents a comparison of single specimens and test specimens assembled with bolts and nuts in a dissimilar metal contact corrosion test, as well as comparisons of precipitation-hardened stainless steel and various types of stainless steel. The test specimens with bolts and nuts were combined and immersed in tap water at 65°C, and for comparison, single specimens (plate-shaped test pieces) were also evaluated. After 45 days of immersion, the test specimens were removed, and photographs of their appearance were taken. We invite you to read it. 【Contents】 ■ Test Method ■ Test Equipment ■ Test Specimen (Single) ■ Test Specimen (Bolt-Nut Combination) ■ Test Results (Single) ■ Test Results (Bolt-Nut Combination) *For more details, please refer to the PDF document or feel free to contact us.
basic information
For more details, please refer to the PDF document or feel free to contact us.
Price range
Delivery Time
Applications/Examples of results
For more details, please refer to the PDF document or feel free to contact us.