Utilize detailed data with virtual sensor functionality | CEW-M4
We will introduce the "virtual sensor" function of the CEW-M4, which allows for a better understanding of detailed improvement points by performing arithmetic operations on the values of physical sensors.
The "virtual sensor function," which allows arithmetic operations on the values of physical sensors, enables the calculation of detailed data that cannot be grasped by physical sensors alone. By utilizing this data, it contributes to visualizing issues and areas for improvement, reducing costs, and enhancing the environment. 【Examples of Utilizing the Virtual Sensor Function】 1. By calculating the total or average values for arbitrary groups, such as by floor or user, it helps identify issues. 2. By using it to calculate the overall PUE of the data center, it contributes to reducing operating hours. 3. By utilizing the discomfort index setting and alarm notification function, it helps create a comfortable working environment. ▽ What is "CEW-M4"? ⇒ It is a manager software compatible with the Modbus protocol that visualizes the values of various sensors and multimeters, achieving energy savings, productivity, and quality improvements. You can implement a power monitoring system that allows for easy setup and operation from the user's perspective. It also comes equipped with a wealth of additional features. For more detailed information, please download the materials or feel free to contact us.
basic information
■Measurement Types: Current, Power, Temperature, Humidity ■Modbus Devices: Various sensor devices, Multimeters ■Measurement Data Collection Cycle: Configurable to 1 minute, 3 minutes, 5 minutes, etc. ■Modbus Gateway: Maximum number of connections: 200 devices ■Relay Device: Maximum number of connections: 200 devices (limited to the maximum number of measurement sensor items) ■Maximum Number of Measurement Sensor Items (Physical Sensors): 20,000 measurement items (Virtual Sensors): 2,000 measurement items ■Interface: Ethernet, COM port ■Input Protocol: Modbus/TCP, Modbus/RTU, Proprietary, MVS (HTTP) ■Output Protocol: SNMP ■Recommended Monitoring Server Operating Environment ・Server OS: Windows Server 2019 ・Server OS: Windows Server 2022 ■Web Client: Microsoft Edge, Mozilla Firefox, Google Chrome *Of the maximum number of items for physical sensors, virtual sensors can accommodate up to 2,000 measurement items. For detailed specifications, please feel free to contact us.
Price range
Delivery Time
Applications/Examples of results
We help visualize values such as current, power, energy consumption, and temperature and humidity, assisting in energy conservation and improving productivity and quality of equipment. 【Main Usage Locations】Data centers, communication equipment, factories, offices, etc. 【Ideal for these concerns】 - Want to combine individually measured values to calculate them by floor or rack unit - Want to reduce the operational burden involved in calculating PUE - Want to efficiently manage temperature and humidity conditions in offices and factories |Please feel free to consult us about system configurations using CEW-M4|
Related Videos
catalog(6)
Download All Catalogs

News about this product(2)
-
We will exhibit at "Interop Tokyo 2025" (Chiba City, Chiba Prefecture).
Our company will be exhibiting at "Interop Tokyo 2025," which will be held at Makuhari Messe from June 11 (Wednesday) to June 13 (Friday), 2025. At this exhibition, we will introduce various products unique to "Hexacore" that can comprehensively propose a one-stop solution for improving the safety and reliability of data centers and streamlining operational management tasks, including distribution boards and measurement and monitoring systems. [Main Exhibited Products] - We will showcase the manager software "CEW-M4," which can accommodate up to 20,000 points, and the Modbus-compatible AC current sensor "PAL-Plus," which has built-in communication functions. - We will present application examples of remote monitoring of UPS batteries utilizing CEW-M4. This is expected to reduce maintenance labor and mitigate risks through early detection of battery deterioration. - AC distribution boards (panel display) We will propose various distribution boards for data centers, from standard specifications to custom-made options. We can also provide sensing distribution boards integrated with our monitoring products. We sincerely look forward to your visit.
-
[Data] Centralized Management of Multiple Locations | CEW-M4×PAL Series Sensors |
Large-scale facilities, where numerous gateways are expected to be installed, can be visualized through centralized management. We have prepared a document summarizing examples of system configurations using the "CEW-M4×PAL series sensors." ▼ Are you facing any of these issues with energy visualization? --- - "I want to manage energy usage across multiple locations centrally." - "I want to use detailed data analysis with high flexibility." - "I want to build a system that excels in scalability and long-term operation." --- ▽ Features - Capable of accommodating up to 20,000 points. - Equipped with a variety of functions such as graph comparison, virtual sensors, and map display. - Compatible with Modbus communication for general use. ▼ What are "PAL series sensors"? Various IoT sensors compatible with Modbus communication that have built-in communication functions. They can be easily introduced in a compact and space-saving manner. 【Utilized Sensors】 - AC current sensor: PAL-Plus (60A) / PAL-Plus large capacity version (up to 630A).