日本システム企画 東京本社  Official site

Leakage prevention measures for the air conditioning piping at Hotel #P.

Case study on the introduction of NMR pipe protectors for preventing red rust and extending the lifespan of hotel air conditioning piping.

At a certain hotel, when it was 40 years old, the deterioration of red rust in the air conditioning chilled and hot water piping made of galvanized steel pipes (SGP) was very advanced, and leaks were occurring at the joints. Therefore, a red rust prevention piping longevity device called "NMR Pipe Protector" was installed. Before the installation of the NMR Pipe Protector, the amount of black rust in the red rust within the hotel's air conditioning chilled and hot water piping was 5.7%. However, six weeks after installation, the amount of black rust increased to 70.8%, demonstrating a relative increase of 1242.1%, proving that the red rust occurring in the air conditioning chilled and hot water piping was reduced to black rust. If the use of the NMR Pipe Protector continues in the future, all red rust in the air conditioning chilled and hot water piping will be reduced to inert black rust with a volume of 1/10, and as long as external corrosion does not occur, leaks from the air conditioning chilled and hot water piping will be prevented, extending the lifespan of the building. Naturally, the replacement of the air conditioning chilled and hot water piping will no longer be necessary.

Leakage prevention measures for the air conditioning piping at Hotel #P | Nippon System Planning Co., Ltd.

basic information

■■■■■ Japan System Planning Co., Ltd. ■■■■■ Toll-Free Number: 0120-320-390 <Free Material Request / Inquiries> https://www.jspkk.co.jp/jp/contact/

Price range

Delivery Time

Applications/Examples of results

Over 4,200 installations!

Related Videos

The method for reducing the repair costs of apartment water pipes was published in the April 11, 2021 issue of Sunday Mainichi!

OTHER

"Methods for Reducing Repair Costs of Hotel Air Conditioning Ducts" was published in the June 25, 2021 issue of "HOTERES" (Weekly Hotel Restaurant)!

OTHER

Recommendation letter from the Royal Garden Hotel London.

OTHER

NMR Pipe Protector Introduction Price Comparison Table (Hotel)

PRICE

Red rust prevention device for piping "NMR Pipe Protector"

PRODUCT

Case Studies of NMR Pipe Protectors

TECHNICAL

Calcium scale solidification adhesion prevention device "Non-Scaler"

PRODUCT

NMR Pipe Protector -NMRPT- for preventing red rust in pipes

PRODUCT

Distributors

Recommended products