【UHS_X-ray CT System Imaging Case】Wire Bonding
This is a case of transmission imaging of wire bonding on a microSD card using a nano-focus X-ray CT system.
last updated
-

【UHS_X-ray CT System Imaging Case】TGV
This is a case of TGV being imaged using transmission and oblique CT with a nano-focus X-ray CT system.
last updated
-

[UHS_X-ray CT System Imaging Case] Smartphone (2018)
This is a case of a smartphone (2018 model) that was imaged using both transparent imaging and oblique CT scanning. It allows for the observation of the internal structure and the condition of the internal memory.
last updated
-

[UHS_X-ray CT System Imaging Example] First Generation Smartphone
This is a case of the first-generation smartphone captured with a transparent image and angled CT scan. It allows for the observation of the internal structure and the condition of the internal memory.
last updated
-

【UHS_X-ray CT System Imaging Case】Heated Tobacco
This is a case of transmission imaging of heated tobacco using the Microfocus X-ray CT system XVA-160RZ.
last updated
-

【UHS_X-ray CT System Imaging Example】Electrolytic Capacitor
This is a case of CT imaging of an electrolytic capacitor using the Microfocus X-ray CT system XVA-160RZ.
last updated
-

【UHS_X-ray CT System Imaging Example】 CT Cross-section of Solder Crack
This is a case where a solder crack was detected by performing CT imaging of an interposer substrate using the Micro Focus X-ray CT system XVA-160RZ.
last updated
-

[UHS_X-ray CT System Imaging Case] QFP_Wire
This is a case where the wire bonding part inside a QFP was enlarged and imaged using orthogonal CT with the Micro Focus X-ray CT system XVA-160RZ.
last updated
-

[UHS X-ray CT System Imaging Case] Effects of Translucent Image Filter Processing
This is a case of filter processing performed using a micro-focus X-ray CT system.
last updated
-

【UHS_X-ray CT System Imaging Case】FET Observation Case
This is a case where a FET was imaged using a micro-focus X-ray CT system XVA-160RZ, and voids were detected.
last updated
-

【UHS_X-ray CT System Imaging Case】QFP Observation Case
This is a case of CT imaging of a QFP using the Micro Focus X-ray CT system XVA-160RZ.
last updated
-

[UHS_X-ray CT System Imaging Example] Smartphone Internal Circuit Board
This is an example of a CT scan of a smartphone's internal circuit board. It is possible to observe the patterns and structures of each internal layer.
last updated
-

[UHS_X-ray CT System Imaging Example] CT Cross-Section of Smartphone-Mounted CPU
This is an example of a CT scan taken of a smartphone-mounted CPU.
last updated