LFC (Liquid Flow Controller)
Burkert's LFC (Liquid Flow Controller) measures and controls liquid flow rates from 15 to 600 ml/min.
Burkert's LFC (Liquid Flow Controller) measures and controls liquid flow rates from 15 to 600 ml/min. Compared to liquid mass flow controllers available on the market, it allows for the control of larger flow rates.
basic information
- Flow range: Span 1:10 Minimum: 0.9 [L/hr] (15 [cc/min]) Maximum: 36 [L/hr] (600 [cc/min]) - Fluid: Non-corrosive, low-viscosity fluids (water, alcohol, low-viscosity oils, etc.) - Fluid pressure: Maximum 0.2 [MPa] Custom products capable of up to 1.0 [MPa] are also available. - Fluid viscosity: 0.4 to 4 cSt - Fluid temperature: 10 to 40℃ - Ambient temperature: 0 to 55℃ - Accuracy: ±1.5% o.R. ±0.5% F.S. - Repeatability: ±0.5% F.S. - Material: Body: Stainless steel Cover: Resin Seal: FKM/EPDM/FFKM selectable - Power supply: DC 24V - Signal: 4-20mA, 0-5V selectable (DeviceNet, Profibus options available) - Protection rating: IP 65 models available
Price information
The price varies depending on the quantity, so please feel free to contact us.
Price range
P3
Delivery Time
OTHER
Model number/Brand name
Type8719
Applications/Examples of results
Semiconductor manufacturing equipment, fuel cells, analytical instruments, food/beverage/pharmaceutical (sterilization) - Pure water flow adjustment - Chemical solution filling - Hydrogen peroxide (H2O2) fumigation sterilization and so on.