Environmental equipment
Environmental equipment
This is an introduction to environmental equipment.
31~43 item / All 43 items
-
[Case Study] Complaints from Neighbors Due to Odor
The measures vary depending on the on-site conditions and the components of the odor! We will introduce countermeasures through adsorption and diffusion.
last updated
-
[Case Study] Response to Legal Revisions Related to Measures for Preventing Health Hazards for Workers
Effective from January 1, 2013! Only the tabletop surface will be newly updated and constructed at a low cost.
last updated
-
[Case Study] Response to Amendments of Specialized Substance Prevention Regulations
Specialized substances require management at suppressive concentrations, so confirmation through measurement is necessary! Introduction of improvement cases.
last updated
-
[Example] Making handling easier by compressing and solidifying dust collected by the dust collector.
Introduction of the dust solidification device (ASH40)! A case study showing how recovery has become easier and storage space has been reduced.
last updated
-
[Case Study] Enabling tasks that are impossible under normal conditions.
Proposing minimal equipment without compromising workability! Introduction of construction examples.
last updated
-
[Example] Preventing corrosion of piping supports by changing the direction of the exhaust outlet.
Corrosion of piping support due to components from the exhaust! We solve environmental issues in factories and production sites.
last updated
-
Improvement of blockage in the duct through changing to the appropriate duct diameter and installing inspection openings.
An example where the duct became less prone to blockage, and installing an inspection port made cleaning easier.
last updated
-
[Case Study] Cleaning Work of Plating Tanks
Introduction of cases where work can be carried out without exposure to dust and high temperatures.
last updated
-
[Case Study] Installation of exhaust fans outside the factory to expel heat from the premises.
Installed ducts with multiple suction ports inside the venue! An example of heat discharge using exhaust fans.
last updated
-
[Case Study] Investigated and installed ventilation equipment to create positive pressure indoors.
Installed an outdoor air processing air conditioner outlet in a room lacking fresh air! A case of creating positive pressure indoors.
last updated
-
Technical Information: Dust Collector Fault Diagnosis
Diagnosing the cause based on symptoms such as "completely stopped inhaling" and "poor inhalation."
last updated
-
[Technical Information] Measures taken by the business operator based on the evaluation of work environment measurement results.
Evaluation of work environment management, such as the 1st management category and the 2nd management category! Introduction of technical information.
last updated
-
Local exhaust system "Original hood design"
Efficiently suction harmful substances (dust, gas, etc.) from the source without compromising workability!
last updated