Free loan of the equipment is also possible! Case studies of trouble resolution in existing plants.

We would like to introduce a case where our "Brodisk" was implemented at a plant engineering company. The customer consulted us, stating that although they were performing aeration, they were unable to resolve the issue of silica fume hanging in the hopper. Based on the hopper diagram (current aeration method and position) and the sample of the material in question, we provided guidance on model selection, layout, and control examples. Following this, the implementation was completed, leading to the resolution of the problem. 【Case Overview】 ■ Hopper Diameter: Φ1600 ■ Outlet Diameter: 200A ■ Contents: Silica fume (ultrafine powder: less than 10μm) ■ Implementation Overview - Arranged 4 standard "Brodisk" units in 2 tiers - A total of 8 "Brodisk" units were used for aeration, with 2 units each *For more details, please download the PDF or feel free to contact us.

Related Link - https://www.mi-nagi.co.jp/2024/12/0688.html

basic information

【Introduced Products】 ■Brodisk Mini: BD-15S-W/4 units ■Controller: C-SV4/1 unit *For more details, please download the PDF or feel free to contact us.