アイテス Official site

Cross-sectional observation of copper terminals and elemental analysis using SEM/EDX.

Investigation of the joint condition and joining methods of crimp terminals, as well as the types of materials! Introduction to cross-sectional observation and elemental analysis using SEM/EDX.

I would like to introduce the topic of "Cross-sectional observation of copper terminals and elemental analysis using SEM/EDX." We conducted cross-section preparation of the joint area of the copper crimp terminal fixture for resistance measurement, applied chemical etching to the prepared cross-section, and observed the metal structure before and after etching. As a result, we infer that the detected elements are P (phosphorus), Ag (silver), and Cu (copper), indicating that it is a silver-containing phosphorus copper solder material. *For more details, please refer to the PDF document or feel free to contact us.*

Related Link - http://www.ites.co.jp/analyze/index.html

basic information

For more details, please refer to the PDF document or feel free to contact us.

Price range

Delivery Time

Applications/Examples of results

For more details, please refer to the PDF document or feel free to contact us.

catalog(17)

Download All Catalogs

Total support service for cross-section grinding, processing, observation, and analysis.

OTHER

[Case Study] X-ray Fluoroscopy and CT Examination Equipment

TECHNICAL

[Example of analysis using EBSD] Screw

PRODUCT

Crystal analysis of Cu using the EBSD method.

PRODUCT

Cross-sectional polishing service for implementation parts and electronic components.

PRODUCT

Tabletop SEM (Scanning Electron Microscope) 'TM3030Plus'

OTHER

[Data] Cross-sectional observation of neodymium magnets using a tabletop SEM (Scanning Electron Microscope)

OTHER

Cross-sectional observation of copper terminals and elemental analysis using SEM/EDX.

OTHER

Observation of aluminum welding joints

TECHNICAL

Cross-sectional observation of large samples (expansion valve)

TECHNICAL

Detection sensitivity due to differences in acceleration voltage during SEM-EDX analysis.

OTHER

Changes due to differences in acceleration voltage during EDX analysis.

OTHER

Basic Analysis Methods for Things that are Similar yet Different

OTHER

Energy Dispersive X-ray Spectroscopy (EDS)

PRODUCT

[Analysis case by EDS] Bonding interface of Cu pad

TECHNICAL

Observation of metallic tissue through chemical treatment.

TECHNICAL

News about this product(1)

Recommended products

Distributors

Aites was established in 1993, originating from the quality assurance department of the IBM Japan Yasu office. Based on the technical expertise cultivated through cutting-edge defect analysis and reliability assurance of electronic components at the IBM Japan Yasu office, we have provided various products and services that support the development and manufacturing of semiconductors, displays, organic EL, solar cells, and electronic components to customers both domestically and internationally.