Analysis case of faulty switch contacts
Appearance inspection, electrical inspection, and internal observation using X-rays conducted! Introduction of analysis cases.
Due to the suspected malfunction at the switch part of the appliance that has stopped powering on, we will introduce a case study along with the work flow. First, we check for any shape changes such as swelling, cracking, or discoloration through visual observation. In the electrical check, we verify whether the malfunction can be reproduced and whether it is an open or short circuit. An internal observation using X-rays revealed that the contact terminals inside the switch had melted, scattered, and disappeared, leading to an open circuit failure. Ultimately, we will submit a report that includes the consideration of the cause. We also welcome inquiries regarding analysis after non-destructive testing, so please feel free to consult us. 【Basics of Non-Destructive Observation】 ■1: Visual Confirmation ■2: Electrical Confirmation ■3: Internal Observation with X-rays *For more details, please refer to the PDF document or feel free to contact us.
basic information
For more details, please refer to the PDF document or feel free to contact us.
Price range
Delivery Time
Applications/Examples of results
For more details, please refer to the PDF document or feel free to contact us.