All products and services
1~30 item / All 63 items
-
Polar Magnetic Water Treatment Device "Rust Prevention, Scale Countermeasures, Slime Suppression"
Prevents rust and enables the long lifespan of piping. Here are examples of effectiveness in air conditioning chilled and hot water piping.
last updated
-
"Scale Adhesion Prevention" Electromagnetic Water Treatment Device 'Hydroflow' *Made in the UK
Maintenance-free! Water treatment device for corrosion prevention, scale adhesion prevention, rust prevention, algae control, and slime prevention.
last updated
-
[Polar Technology Case] Confirmation of anti-corrosion effect on air conditioning chilled and hot water pipes after 17 years and 5 months.
The remaining lifespan prediction for the cold and hot water pipes is over 20 years! Thanks to Polar's rust prevention effect, there are no rust lumps on the inner surface of the pipes.
last updated
-
Examples of Corrosion Prevention Effects of Cold and Warm Water [Magnetic Water Treatment Device Vol. 2]
Comparing water samples before and after treatment, the corrosion prevention effect is clear at a glance!
last updated
-
Case study of the new chilled and hot water pipes after 5 years [Magnetic Water Treatment Device Vol. 3]
Confirmed the formation of an extremely thin, dense, and uniform corrosion-resistant coating in white (inorganic).
last updated
-
Corrosion prevention effect of chilled and hot water in hospital air conditioning systems [Magnetic Water Treatment Device Vol. 4]
A case where an electric control valve, which had failed and been replaced six times before installation, experienced no failures after installation.
last updated
-
Corrosion prevention effect of newly built air conditioning chilled and hot water【Magnetic water treatment device Vol.5】
The iron content of the treated hot and cold water has decreased from 0.15 to less than 0.05, a reduction of one third!
last updated
-
Case Study on the Corrosion Prevention Effect of Chilled Water in Air Conditioning Systems [Magnetic Water Treatment Device Vol. 6]
Installed on the supply header outlet side! An example showing a dark brown color compared to the untreated side.
last updated
-
Corrosion and scale prevention for chilled water in air conditioning systems [Magnetic Water Treatment Device Vol. 7]
The water quality in the pipe is weakly alkaline! The pH has risen, iron content is low, the water is clear, and the corrosion resistance is significant.
last updated
-
Red Water Prevention Measures [Magnetic Water Treatment Device Vol. 1]
Four large polar units installed using the independent circulation method! Introduced for corrosion protection of the water supply piping and the entire facility.
last updated
-
About the cause of red water (300 households) [Magnetic water treatment device Vol. 2]
We will introduce examples of conducting water main extraction in various housing complexes and investigating corrosion within the pipes!
last updated
-
Red water countermeasures (86 households, 17 years after construction) [Magnetic water treatment device Vol. 3]
A longevity measure to suppress the deterioration of water supply pipes and prevent scaling! Installed in a 17-year-old apartment building with 86 households.
last updated
-
Red Water Countermeasures (27 years after construction, 271 households) [Magnetic Water Treatment Device Vol. 4]
Everyone is surprised by the speed of the effect! Here’s an example where the red water stopped in about a week after installation.
last updated
-
Red water countermeasures (18 years after construction, 85 households) [Magnetic water treatment device Vol. 5]
A complete Polar model PI-50CF is installed with a dedicated pump for independent circulation in a 40m3 water storage tank!
last updated
-
Red Water Countermeasures (13 Years After Construction, 30 Households) [Magnetic Water Treatment Device Vol. 6]
Adopting an independent circulation system! Installing PI-25CF (3-piece set) in a 13-year-old, 30-unit apartment building.
last updated
-
Red water prevention measures (13 years after construction) [Magnetic water treatment device Vol. 7]
Confirmed that the chromaticity has greatly improved! A case of installing the Polar model PI-25CF in a water storage tank.
last updated
-
Countermeasures for Red Water (2.5 Years After Construction) [Magnetic Water Treatment Device Vol. 8]
All analysis items are within drinking water quality standards! Cases demonstrating effects equivalent to those of chemical treatment.
last updated
-
Red Water Measures (Hotel Hot Water) [Magnetic Water Treatment Device Vol. 9]
Installed with a partial bypass method on return pipe 65A! Introduction of a case where red rust in the boiler turned into black rust and red water stopped.
last updated
-
Red Water Countermeasures (Water Supply and Hot Water Supply for Large Buildings) [Magnetic Water Treatment Device Vol. 10]
We installed a polar magnetic water treatment device! We will introduce a case where the red water completely improved and stopped after 6 months.
last updated
-
Red Water Measures (Hot Water Supply of Large Hospitals) [Magnetic Water Treatment Device Vol. 11]
This is an introduction to a case where water quality improvement was achieved through the effects of a polar magnetic water treatment device!
last updated
-
Red Water Measures (Hotel Hot Water) [Magnetic Water Treatment Device Vol. 12]
We will introduce a case where the red water completely stopped, the water became clear, and the troubles were resolved!
last updated
-
Case Study on Red Rust Removal Effect of Cooling Water (Chiller Water) [Magnetic Water Treatment Device Vol. 1]
Conducting a test to confirm the effectiveness of rust removal! After the test, we will introduce cases where the rust was beautifully removed.
last updated
-
Cooling water (chiller water) molding machine mold case study [Magnetic water treatment device Vol. 2]
Cooling water volume increased by 16%! Red rust has been completely removed and changed to black rust.
last updated
-
Examples of Softening and Dissolution of Cooling Water System Scale [Magnetic Water Treatment Device Vol. 3]
Comparison before and after use (2.5 months)! The softening and dissolution of the scale was confirmed.
last updated
-
Scale prevention measures for turbo refrigeration units used in air conditioning [Magnetic water treatment device Vol. 4]
A demonstration experiment aimed at comparing the effects of polar magnetic water treatment devices and chemical treatment.
last updated
-
Scale Prevention for Absorption Chiller-Heating Water Generators [Magnetic Water Treatment Device Vol. 5]
Due to the slime suppression effect, there is no slime at all! The prevention of scale adhesion and the anti-corrosion effect have been significantly demonstrated.
last updated
-
Case Study on Scale Prevention in Closed Cooling Towers [Magnetic Water Treatment Device Vol. 6]
We will introduce a case where we successfully confirmed the absence of scale attachment and saved on water costs!
last updated
-
Cooling water (Plate heat exchanger for cogeneration) [Magnetic water treatment device Vol. 7]
We present a case where over 95% of the adhesion was removed, and cleaning was completed with a simple jet wash!
last updated
-
Cooling water (oil cooler heat exchanger) [Magnetic water treatment device Vol. 8]
The scale and water algae on the surface of the copper pipe have fallen off, improving thermal efficiency!
last updated
-
Cooling water (refrigeration unit and oil cooler) [Magnetic water treatment device Vol. 9]
Effect on rust on the inner surface of pipes, how effective is it against scale adhesion?
last updated